GasCompressLab

Weymouth · Panhandle B · RP 14E

Weymouth trunkline transfer

A 356 mm ID trunkline carries 54,000 Nm³/h of sweet gas through a mild uphill run.

What to check

Compare inlet and outlet velocity even where the pressure loss is modest.

Operating readout

Edit inputs ↓
Outlet press.
5,955.13kPa(a)
Pressure drop
294.87kPa
Outlet velocity
2.54m/s
Erosion use
14.69%
Within velocity screening limitThe outlet is within the selected API RP 14E comparison value.
Gas line section and longitudinal pressure profileISOTHERMAL GAS LINEkPa(a)P₁ 6250P₂ 5960Δz 110 mLONGITUDINAL PRESSUREkPa(a)62505960037 kmOUTLET EROSION USE14.7%
The line follows the entered elevation change. The plot uses the pressure-squared model at each distance along the run.
Calculated details
Inlet gas velocity
2.42m/s
Inlet RP 14E comparison
16.86m/s
Outlet RP 14E comparison
17.27m/s
Inlet gas density
52.34kg/m³
Outlet gas density
49.87kg/m³
Elevation correction exponent
0.01807
Outlet isothermal Mach
0.0073
Mass flow used
45,358.83kg/h

Operating inputs

Pipeline duty
kPa(a)
Nm³/h
km
mm
m
Positive for an uphill run.
Gas and resistance
°C
%

Calculation basis

Solve the pressure-squared balance

With constant Z and temperature, use s = 2gΔz/(ZRₛT) and equivalent length L·expm1(s)/s. Solve for P₂ in the pressure-squared difference P₁² − eˢP₂². The Darcy mode uses the entered friction factor. Weymouth and Panhandle B use their published US-unit flow coefficients.

Compare velocity

Convert standard volumetric flow to mass, then divide by local density and flow area. The RP 14E comparison is C/√ρ in ft/s with density in lb/ft³. The outlet governs for a declining, isothermal pressure profile.