Units & reference conditions

Choose the reference basis before entering a value. The SI and US selectors keep the same physical case and change the display.

QuantitySIUS processBasis
Absolute pressurekPa(a), bar(a)psiaReferenced to vacuum. Enter suction and flowing pressure on this basis.
Gauge pressurebar(g)psigReferenced to local atmosphere. The PSV calculation adds the entered atmospheric pressure once.
Absolute temperature input°C°FConverted to kelvin internally. Temperatures below or equal to absolute zero are invalid.
Temperature differenceKΔ°FA 1 K interval is 1.8 °F. Apply the scale without a temperature offset.
Gas quantity at baseNm³/hMMSCFDSI base is 0 °C and 101.325 kPa(a). US base is 60 °F and 14.696 psia. The conversion accounts for both base states.
Actual gas volumem³/hACFMVolume at the process condition. Convert to mass using local density.
Gas power and thermal dutykWhp / MMBtu/hShaft and equipment work use mechanical horsepower. Flare heat release uses MMBtu/h.
Flow areas and lengthsmm², mm, m, kmin², in, ft, miGas orifice calculations use effective area. Pipeline calculations require inside diameter.

Standard flow and density

Normal and standard volumes in this site assume ideal reference-gas conditions. An entered Z applies at the modeled process state. For a contractual base such as 14.65 psia, convert by gas density to the site basis before entering flow.

Read the calculation methods →