Engineering reference
Units & reference conditions
Choose the reference basis before entering a value. The SI and US selectors keep the same physical case and change the display.
| Quantity | SI | US process | Basis |
|---|---|---|---|
| Absolute pressure | kPa(a), bar(a) | psia | Referenced to vacuum. Enter suction and flowing pressure on this basis. |
| Gauge pressure | bar(g) | psig | Referenced to local atmosphere. The PSV calculation adds the entered atmospheric pressure once. |
| Absolute temperature input | °C | °F | Converted to kelvin internally. Temperatures below or equal to absolute zero are invalid. |
| Temperature difference | K | Δ°F | A 1 K interval is 1.8 °F. Apply the scale without a temperature offset. |
| Gas quantity at base | Nm³/h | MMSCFD | SI base is 0 °C and 101.325 kPa(a). US base is 60 °F and 14.696 psia. The conversion accounts for both base states. |
| Actual gas volume | m³/h | ACFM | Volume at the process condition. Convert to mass using local density. |
| Gas power and thermal duty | kW | hp / MMBtu/h | Shaft and equipment work use mechanical horsepower. Flare heat release uses MMBtu/h. |
| Flow areas and lengths | mm², mm, m, km | in², in, ft, mi | Gas orifice calculations use effective area. Pipeline calculations require inside diameter. |
Standard flow and density
Normal and standard volumes in this site assume ideal reference-gas conditions. An entered Z applies at the modeled process state. For a contractual base such as 14.65 psia, convert by gas density to the site basis before entering flow.
Read the calculation methods →