Symmetric −3% to +3% sag

Find the low point and compare its curvature rate with a required sight distance.

More examples

Field inputs

Switching the unit converts the inputs.

Tangent grades
Stopping sight distance

Enter the stopping sight distance adopted for the project. A positive grade rises in increasing station order.

Survey anatomy

Profile & sight-distance check

Edit inputs
Profile & sight-distance checkLive plot with four readings and a check bar. SSD geometry. Meets geometry.PROFILESagK RATE66.667ft/%CURVE LENGTH400ftSSD MIN. L381.0525ftTANGENT GRADESLOW POINTPVCPVIPVTSSD geometryMeets geometry
Diagram proportions adapt to the inputs. Use the computed readings for field dimensions.

Computed results

Meets geometry

Tangent and curve controls

PVC
19+00.000ft
PVC elevation
606ft
PVI
21+00.000ft
PVI tangent elevation
600ft
PVT
23+00.000ft
PVT elevation
606ft
Grade difference A
6%
K rate
66.66667ft/%
Low point station
21+00.000ft
Low point elevation
603ft
Turning point grade
0%

Stopping sight distance check

Required sight distance S
305ft
Geometric minimum L
381.05246ft
Geometric minimum K
63.50874ft/%
Long-curve K at S
63.50874ft/%
Sizing branch
S ≤ L

Profile elevations and grades

PointStationftOffset from PVCftElevationftGrade%
PVC19+00.0000606−3
Stake19+50.00050604.6875−2.25
Stake20+00.000100603.75−1.5
Stake20+50.000150603.1875−0.75
Low point21+00.0002006030
Stake21+50.000250603.18750.75
Stake22+00.000300603.751.5
Stake22+50.000350604.68752.25
PVT23+00.0004006063

Worked check

The tangents meet at 600 ft and the parabola is 3 ft above that intersection at the low point. The 400 ft curve exceeds the geometric length required for the input SSD.

Low-point elevation (ft)
603
Curvature rate (ft/%)
66.6666667
Meets geometric SSD check
Yes

These checks describe the original example. Reset restores the original inputs.

Formulas and conventions

Build the symmetric profile

A = g₂ − g₁ · z(x) = zPVC + g₁x ÷ 100 + Ax² ÷ (200L)

PVC and PVT are L/2 either side of the tangent intersection PVI. Grades are entered in percent. When grades have opposite signs, x = −g₁L/A is the interior turning point and its slope is exactly zero.

Join unequal tangents

gⱼ = (L₁g₁ + L₂g₂) ÷ L · zⱼ = zPVI + A L₁ L₂ ÷ (200L)

L₁ is PVC to PVI and L₂ is PVI to PVT. Each parabola integrates a linear grade between the endpoint and common join grade. Find the zero grade on the piece where the signs change. The local K values are L₁/|gⱼ − g₁| and L₂/|g₂ − gⱼ|.

Calculate the curvature rate

K = L ÷ |A|

K is length per percentage point of grade change. Equal grades form a straight tangent and have no finite K. Station labels use 100-foot stations or kilometer plus meters, depending on the working unit.

Compare the SSD geometry

Lmin = |A| S² ÷ C when Lmin ≥ S · otherwise max(0, 2S − C ÷ |A|)

For a crest, C = 200(√h₁ + √h₂)², with eye height 3.5 ft and object height 2 ft. For a sag, C = 200(h + S tan 1°), with headlight height 2 ft. The two minimum-length branches apply to equal tangents. Unequal tangents use a sufficient screen: both local K values must meet S²/C. If either is tighter, check the complete sight line. Use the adopted agency criteria and drainage controls.

More worked examples

Open a case to edit its inputs and compare the original checks.

Share editable inputs

The link contains the entered field values. Share it with people who should see those values.