Worked example
Exit cell spacing and piping margin
A filter study examines a relatively long spacing between the last equipotentials at the toe.
Results
Edit inputs ↓- Darcy flow
- 1.60e-4 m³/s
- Pore velocity
- 9.18e-5 m/s
- Exit gradient
- 0.273
- Exit F.S.
- 3.9
- Flow line
- Potential drop
- Exit cell
The upward exit gradient meets the entered safety-factor target.
Calculation details
| Average Darcy gradient ΔH/L | 0.3333 |
|---|---|
| Darcy velocity | 3.33e-5 m/s |
| Porosity from exit soil void ratio | 36.3 % |
| Flow-net discharge per unit width | 1.50e-4 m²/s |
| Head loss per potential drop | 0.3 m |
| Critical upward gradient | 1.064 |
| Target maximum exit gradient | 0.355 |
GeotechSoilLab · Screening sheet · Metric SI
Exit cell spacing and piping margin
| Head difference ΔH | 3 m |
|---|---|
| Seepage length L | 9 m |
| Hydraulic conductivity k | 1.00e-4 m/s |
| Cross-section A | 4.8 m² |
| Flow channels Nf | 5 |
| Potential drops Nd | 10 |
| Final drop spacing | 1.1 m |
| Solids specific gravity Gs | 2.67 |
| Exit soil void ratio e | 0.57 |
| Target exit safety factor | 3 |
| Darcy flow | 1.60e-4 m³/s |
|---|---|
| Pore velocity | 9.18e-5 m/s |
| Exit gradient | 0.273 |
| Exit F.S. | 3.9 |
| Average Darcy gradient ΔH/L | 0.3333 |
| Darcy velocity | 3.33e-5 m/s |
| Porosity from exit soil void ratio | 36.3 % |
| Flow-net discharge per unit width | 1.50e-4 m²/s |
| Head loss per potential drop | 0.3 m |
| Critical upward gradient | 1.064 |
| Target maximum exit gradient | 0.355 |
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Worked result
Changing final spacing changes the exit check while leaving total isotropic flow-net discharge unchanged.
- Divide 3 m by 9 m for i = 0.3333. Multiply ki by the section area to get Q = 1.60e-4 m³/s.
- Use 5 flow channels and 10 potential drops for 1.50e-4 m²/s per unit width.
- The final head drop gives an exit gradient of 0.2727. Divide the critical gradient 1.0637 by that value for exit F.S. = 3.9.
Darcy flow1.60e-4 m³/sPore velocity9.18e-5 m/sExit gradient0.273Exit F.S.3.9
Original case inputs
| Head difference ΔH | 3 m |
|---|---|
| Seepage length L | 9 m |
| Hydraulic conductivity k | 1.00e-4 m/s |
| Cross-section A | 4.8 m² |
| Flow channels Nf | 5 |
| Potential drops Nd | 10 |
| Final drop spacing | 1.1 m |
| Solids specific gravity Gs | 2.67 |
| Exit soil void ratio e | 0.57 |
| Target exit safety factor | 3 |
Method & assumptions
- For steady one-dimensional flow, i = ΔH/L, v = ki and Q = vA. Average pore velocity is v/n with n = e/(1 + e).
- For an isotropic two-dimensional flow net, discharge per unit width is kΔH Nf/Nd. Count channels and potential drops as spaces between the drawn lines.
- The local upward exit gradient uses the final head drop ΔH/Nd divided by its spacing measured along the exiting streamline. The bulk Darcy gradient ΔH/L describes the full path.
- Use i꜀ᵣ = (Gs − 1)/(1 + e) and F.S. = i꜀ᵣ/iₑₓᵢₜ as a boiling screen for cohesionless exit soil. Check filters, internal erosion and field flow geometry separately.
More worked examples
- Darcy flow through a sand columnA bench permeameter measures steady flow through a small sand cross-section.
- Flow net below a sheet pile cutoffAn illustrative two-dimensional flow net under a cutoff has five flow channels and fourteen potential drops.
- Upward exit near the boiling gradientAn upward exit through fine sand has a short last potential cell.
- Low-conductivity silt seepageA silty layer transmits a small steady discharge under a sustained head difference.
- Equal head across a seepage sectionWater levels are equal across the section in a steady-state snapshot.