Worked example

Exit cell spacing and piping margin

A filter study examines a relatively long spacing between the last equipotentials at the toe.

Darcy flow
1.60e-4 m³/s
Pore velocity
9.18e-5 m/s
Exit gradient
0.273
Exit F.S.
3.9
Flow net & upward exit Schematic
Flow net & upward exit, schematic UpstreamDownstreamΔH 3 m5 channels / 10 dropsExit F.S. / 33.9
  • Flow line
  • Potential drop
  • Exit cell

The upward exit gradient meets the entered safety-factor target.

Calculation details
Average Darcy gradient ΔH/L0.3333
Darcy velocity3.33e-5 m/s
Porosity from exit soil void ratio36.3 %
Flow-net discharge per unit width1.50e-4 m²/s
Head loss per potential drop0.3 m
Critical upward gradient1.064
Target maximum exit gradient0.355

Inputs

Darcy flow section
Flow net and upward exit
Used to derive porosity and the boiling gradient.

Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.

Worked result

Changing final spacing changes the exit check while leaving total isotropic flow-net discharge unchanged.

  1. Divide 3 m by 9 m for i = 0.3333. Multiply ki by the section area to get Q = 1.60e-4 m³/s.
  2. Use 5 flow channels and 10 potential drops for 1.50e-4 m²/s per unit width.
  3. The final head drop gives an exit gradient of 0.2727. Divide the critical gradient 1.0637 by that value for exit F.S. = 3.9.
Darcy flow1.60e-4 m³/sPore velocity9.18e-5 m/sExit gradient0.273Exit F.S.3.9
Original case inputs
Head difference ΔH3 m
Seepage length L9 m
Hydraulic conductivity k1.00e-4 m/s
Cross-section A4.8 m²
Flow channels Nf5
Potential drops Nd10
Final drop spacing1.1 m
Solids specific gravity Gs2.67
Exit soil void ratio e0.57
Target exit safety factor3

Method & assumptions

  1. For steady one-dimensional flow, i = ΔH/L, v = ki and Q = vA. Average pore velocity is v/n with n = e/(1 + e).
  2. For an isotropic two-dimensional flow net, discharge per unit width is kΔH Nf/Nd. Count channels and potential drops as spaces between the drawn lines.
  3. The local upward exit gradient uses the final head drop ΔH/Nd divided by its spacing measured along the exiting streamline. The bulk Darcy gradient ΔH/L describes the full path.
  4. Use i꜀ᵣ = (Gs − 1)/(1 + e) and F.S. = i꜀ᵣ/iₑₓᵢₜ as a boiling screen for cohesionless exit soil. Check filters, internal erosion and field flow geometry separately.