Worked example

Darcy flow through a sand column

A bench permeameter measures steady flow through a small sand cross-section.

Darcy flow
6.93e-6 m³/s
Pore velocity
1.52e-4 m/s
Exit gradient
0.361
Exit F.S.
2.87
Flow net & upward exit Schematic
Flow net & upward exit, schematic UpstreamDownstreamΔH 0.65 m2 channels / 6 dropsExit F.S. / 32.87
  • Flow line
  • Potential drop
  • Exit cell

The upward exit gradient exceeds the target. Review local exit conditions and filters.

Calculation details
Average Darcy gradient ΔH/L0.3611
Darcy velocity5.78e-5 m/s
Porosity from exit soil void ratio37.9 %
Flow-net discharge per unit width3.47e-5 m²/s
Head loss per potential drop0.108 m
Critical upward gradient1.037
Target maximum exit gradient0.346

Inputs

Darcy flow section
Flow net and upward exit
Used to derive porosity and the boiling gradient.

Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.

Worked result

Divide Darcy velocity by porosity for the mean pore-water velocity.

  1. Divide 0.65 m by 1.8 m for i = 0.3611. Multiply ki by the section area to get Q = 6.93e-6 m³/s.
  2. Use 2 flow channels and 6 potential drops for 3.47e-5 m²/s per unit width.
  3. The final head drop gives an exit gradient of 0.3611. Divide the critical gradient 1.0373 by that value for exit F.S. = 2.872.
Darcy flow6.93e-6 m³/sPore velocity1.52e-4 m/sExit gradient0.361Exit F.S.2.87
Original case inputs
Head difference ΔH0.65 m
Seepage length L1.8 m
Hydraulic conductivity k1.60e-4 m/s
Cross-section A0.12 m²
Flow channels Nf2
Potential drops Nd6
Final drop spacing0.3 m
Solids specific gravity Gs2.67
Exit soil void ratio e0.61
Target exit safety factor3

Method & assumptions

  1. For steady one-dimensional flow, i = ΔH/L, v = ki and Q = vA. Average pore velocity is v/n with n = e/(1 + e).
  2. For an isotropic two-dimensional flow net, discharge per unit width is kΔH Nf/Nd. Count channels and potential drops as spaces between the drawn lines.
  3. The local upward exit gradient uses the final head drop ΔH/Nd divided by its spacing measured along the exiting streamline. The bulk Darcy gradient ΔH/L describes the full path.
  4. Use i꜀ᵣ = (Gs − 1)/(1 + e) and F.S. = i꜀ᵣ/iₑₓᵢₜ as a boiling screen for cohesionless exit soil. Check filters, internal erosion and field flow geometry separately.

More worked examples