Worked example
Darcy flow through a sand column
A bench permeameter measures steady flow through a small sand cross-section.
Results
Edit inputs ↓- Darcy flow
- 6.93e-6 m³/s
- Pore velocity
- 1.52e-4 m/s
- Exit gradient
- 0.361
- Exit F.S.
- 2.87
- Flow line
- Potential drop
- Exit cell
The upward exit gradient exceeds the target. Review local exit conditions and filters.
Calculation details
| Average Darcy gradient ΔH/L | 0.3611 |
|---|---|
| Darcy velocity | 5.78e-5 m/s |
| Porosity from exit soil void ratio | 37.9 % |
| Flow-net discharge per unit width | 3.47e-5 m²/s |
| Head loss per potential drop | 0.108 m |
| Critical upward gradient | 1.037 |
| Target maximum exit gradient | 0.346 |
GeotechSoilLab · Screening sheet · Metric SI
Darcy flow through a sand column
| Head difference ΔH | 0.65 m |
|---|---|
| Seepage length L | 1.8 m |
| Hydraulic conductivity k | 1.60e-4 m/s |
| Cross-section A | 0.12 m² |
| Flow channels Nf | 2 |
| Potential drops Nd | 6 |
| Final drop spacing | 0.3 m |
| Solids specific gravity Gs | 2.67 |
| Exit soil void ratio e | 0.61 |
| Target exit safety factor | 3 |
| Darcy flow | 6.93e-6 m³/s |
|---|---|
| Pore velocity | 1.52e-4 m/s |
| Exit gradient | 0.361 |
| Exit F.S. | 2.87 |
| Average Darcy gradient ΔH/L | 0.3611 |
| Darcy velocity | 5.78e-5 m/s |
| Porosity from exit soil void ratio | 37.9 % |
| Flow-net discharge per unit width | 3.47e-5 m²/s |
| Head loss per potential drop | 0.108 m |
| Critical upward gradient | 1.037 |
| Target maximum exit gradient | 0.346 |
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Worked result
Divide Darcy velocity by porosity for the mean pore-water velocity.
- Divide 0.65 m by 1.8 m for i = 0.3611. Multiply ki by the section area to get Q = 6.93e-6 m³/s.
- Use 2 flow channels and 6 potential drops for 3.47e-5 m²/s per unit width.
- The final head drop gives an exit gradient of 0.3611. Divide the critical gradient 1.0373 by that value for exit F.S. = 2.872.
Darcy flow6.93e-6 m³/sPore velocity1.52e-4 m/sExit gradient0.361Exit F.S.2.87
Original case inputs
| Head difference ΔH | 0.65 m |
|---|---|
| Seepage length L | 1.8 m |
| Hydraulic conductivity k | 1.60e-4 m/s |
| Cross-section A | 0.12 m² |
| Flow channels Nf | 2 |
| Potential drops Nd | 6 |
| Final drop spacing | 0.3 m |
| Solids specific gravity Gs | 2.67 |
| Exit soil void ratio e | 0.61 |
| Target exit safety factor | 3 |
Method & assumptions
- For steady one-dimensional flow, i = ΔH/L, v = ki and Q = vA. Average pore velocity is v/n with n = e/(1 + e).
- For an isotropic two-dimensional flow net, discharge per unit width is kΔH Nf/Nd. Count channels and potential drops as spaces between the drawn lines.
- The local upward exit gradient uses the final head drop ΔH/Nd divided by its spacing measured along the exiting streamline. The bulk Darcy gradient ΔH/L describes the full path.
- Use i꜀ᵣ = (Gs − 1)/(1 + e) and F.S. = i꜀ᵣ/iₑₓᵢₜ as a boiling screen for cohesionless exit soil. Check filters, internal erosion and field flow geometry separately.
More worked examples
- Flow net below a sheet pile cutoffAn illustrative two-dimensional flow net under a cutoff has five flow channels and fourteen potential drops.
- Upward exit near the boiling gradientAn upward exit through fine sand has a short last potential cell.
- Low-conductivity silt seepageA silty layer transmits a small steady discharge under a sustained head difference.
- Equal head across a seepage sectionWater levels are equal across the section in a steady-state snapshot.
- Exit cell spacing and piping marginA filter study examines a relatively long spacing between the last equipotentials at the toe.