Worked example

Flow net below a sheet pile cutoff

An illustrative two-dimensional flow net under a cutoff has five flow channels and fourteen potential drops.

Darcy flow
0.02039 ft³/s
Pore velocity
4.56e-4 ft/s
Exit gradient
0.353
Exit F.S.
2.77
Flow net & upward exit Schematic
Flow net & upward exit, schematic UpstreamDownstreamΔH 13.78 ft5 channels / 14 dropsExit F.S. / 32.77
  • Flow line
  • Potential drop
  • Exit cell

The upward exit gradient exceeds the target. Review local exit conditions and filters.

Calculation details
Average Darcy gradient ΔH/L0.2625
Darcy velocity1.89e-4 ft/s
Porosity from exit soil void ratio41.5 %
Flow-net discharge per unit width0.00355 ft²/s
Head loss per potential drop0.984 ft
Critical upward gradient0.977
Target maximum exit gradient0.326

Inputs

Darcy flow section
Flow net and upward exit
Used to derive porosity and the boiling gradient.

Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.

Worked result

Flow-net discharge is reported per unit width. The spacing of the last cell controls the local exit gradient.

  1. Divide 13.78 ft by 52.493 ft for i = 0.2625. Multiply ki by the section area to get Q = 0.020394 ft³/s.
  2. Use 5 flow channels and 14 potential drops for 0.003552 ft²/s per unit width.
  3. The final head drop gives an exit gradient of 0.3529. Divide the critical gradient 0.9766 by that value for exit F.S. = 2.767.
Darcy flow0.02039 ft³/sPore velocity4.56e-4 ft/sExit gradient0.353Exit F.S.2.77
Original case inputs
Head difference ΔH13.77953 ft
Seepage length L52.49344 ft
Hydraulic conductivity k7.22e-4 ft/s
Cross-section A107.6391 ft²
Flow channels Nf5
Potential drops Nd14
Final drop spacing2.78871 ft
Solids specific gravity Gs2.67
Exit soil void ratio e0.71
Target exit safety factor3

Method & assumptions

  1. For steady one-dimensional flow, i = ΔH/L, v = ki and Q = vA. Average pore velocity is v/n with n = e/(1 + e).
  2. For an isotropic two-dimensional flow net, discharge per unit width is kΔH Nf/Nd. Count channels and potential drops as spaces between the drawn lines.
  3. The local upward exit gradient uses the final head drop ΔH/Nd divided by its spacing measured along the exiting streamline. The bulk Darcy gradient ΔH/L describes the full path.
  4. Use i꜀ᵣ = (Gs − 1)/(1 + e) and F.S. = i꜀ᵣ/iₑₓᵢₜ as a boiling screen for cohesionless exit soil. Check filters, internal erosion and field flow geometry separately.

More worked examples