Worked example
Flow net below a sheet pile cutoff
An illustrative two-dimensional flow net under a cutoff has five flow channels and fourteen potential drops.
Results
Edit inputs ↓- Darcy flow
- 0.02039 ft³/s
- Pore velocity
- 4.56e-4 ft/s
- Exit gradient
- 0.353
- Exit F.S.
- 2.77
- Flow line
- Potential drop
- Exit cell
The upward exit gradient exceeds the target. Review local exit conditions and filters.
Calculation details
| Average Darcy gradient ΔH/L | 0.2625 |
|---|---|
| Darcy velocity | 1.89e-4 ft/s |
| Porosity from exit soil void ratio | 41.5 % |
| Flow-net discharge per unit width | 0.00355 ft²/s |
| Head loss per potential drop | 0.984 ft |
| Critical upward gradient | 0.977 |
| Target maximum exit gradient | 0.326 |
GeotechSoilLab · Screening sheet · US customary
Flow net below a sheet pile cutoff
| Head difference ΔH | 13.77953 ft |
|---|---|
| Seepage length L | 52.49344 ft |
| Hydraulic conductivity k | 7.22e-4 ft/s |
| Cross-section A | 107.6391 ft² |
| Flow channels Nf | 5 |
| Potential drops Nd | 14 |
| Final drop spacing | 2.78871 ft |
| Solids specific gravity Gs | 2.67 |
| Exit soil void ratio e | 0.71 |
| Target exit safety factor | 3 |
| Darcy flow | 0.02039 ft³/s |
|---|---|
| Pore velocity | 4.56e-4 ft/s |
| Exit gradient | 0.353 |
| Exit F.S. | 2.77 |
| Average Darcy gradient ΔH/L | 0.2625 |
| Darcy velocity | 1.89e-4 ft/s |
| Porosity from exit soil void ratio | 41.5 % |
| Flow-net discharge per unit width | 0.00355 ft²/s |
| Head loss per potential drop | 0.984 ft |
| Critical upward gradient | 0.977 |
| Target maximum exit gradient | 0.326 |
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Worked result
Flow-net discharge is reported per unit width. The spacing of the last cell controls the local exit gradient.
- Divide 13.78 ft by 52.493 ft for i = 0.2625. Multiply ki by the section area to get Q = 0.020394 ft³/s.
- Use 5 flow channels and 14 potential drops for 0.003552 ft²/s per unit width.
- The final head drop gives an exit gradient of 0.3529. Divide the critical gradient 0.9766 by that value for exit F.S. = 2.767.
Darcy flow0.02039 ft³/sPore velocity4.56e-4 ft/sExit gradient0.353Exit F.S.2.77
Original case inputs
| Head difference ΔH | 13.77953 ft |
|---|---|
| Seepage length L | 52.49344 ft |
| Hydraulic conductivity k | 7.22e-4 ft/s |
| Cross-section A | 107.6391 ft² |
| Flow channels Nf | 5 |
| Potential drops Nd | 14 |
| Final drop spacing | 2.78871 ft |
| Solids specific gravity Gs | 2.67 |
| Exit soil void ratio e | 0.71 |
| Target exit safety factor | 3 |
Method & assumptions
- For steady one-dimensional flow, i = ΔH/L, v = ki and Q = vA. Average pore velocity is v/n with n = e/(1 + e).
- For an isotropic two-dimensional flow net, discharge per unit width is kΔH Nf/Nd. Count channels and potential drops as spaces between the drawn lines.
- The local upward exit gradient uses the final head drop ΔH/Nd divided by its spacing measured along the exiting streamline. The bulk Darcy gradient ΔH/L describes the full path.
- Use i꜀ᵣ = (Gs − 1)/(1 + e) and F.S. = i꜀ᵣ/iₑₓᵢₜ as a boiling screen for cohesionless exit soil. Check filters, internal erosion and field flow geometry separately.
More worked examples
- Darcy flow through a sand columnA bench permeameter measures steady flow through a small sand cross-section.
- Upward exit near the boiling gradientAn upward exit through fine sand has a short last potential cell.
- Low-conductivity silt seepageA silty layer transmits a small steady discharge under a sustained head difference.
- Equal head across a seepage sectionWater levels are equal across the section in a steady-state snapshot.
- Exit cell spacing and piping marginA filter study examines a relatively long spacing between the last equipotentials at the toe.