Worked example

Equal head across a seepage section

Water levels are equal across the section in a steady-state snapshot.

Darcy flow
0 m³/s
Pore velocity
0 m/s
Exit gradient
0
Exit F.S.
—
Flow net & upward exit Schematic
Flow net & upward exit, schematic UpstreamDownstreamΔH 0 m4 channels / 10 dropsExit F.S. / 3Equal head
  • Flow line
  • Potential drop
  • Exit cell

No head difference. Flow is zero and the exit safety factor is undefined.

Calculation details
Average Darcy gradient ΔH/L0
Darcy velocity0 m/s
Porosity from exit soil void ratio39 %
Flow-net discharge per unit width0 m²/s
Head loss per potential drop0 m
Critical upward gradient1.018
Target maximum exit gradient0.339

Inputs

Darcy flow section
Flow net and upward exit
Used to derive porosity and the boiling gradient.

Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.

Worked result

Discharge and exit gradient are zero. The ratio of critical gradient to zero exit gradient is unavailable.

  1. Divide 0 m by 10 m for i = 0. Multiply ki by the section area to get Q = 0 m³/s.
  2. Use 4 flow channels and 10 potential drops for 0 m²/s per unit width.
  3. The final head drop is zero, so the exit-gradient ratio is undefined.
Darcy flow0 m³/sPore velocity0 m/sExit gradient0Exit F.S.—
Original case inputs
Head difference ΔH0 m
Seepage length L10 m
Hydraulic conductivity k1.80e-4 m/s
Cross-section A2.7 m²
Flow channels Nf4
Potential drops Nd10
Final drop spacing0.65 m
Solids specific gravity Gs2.67
Exit soil void ratio e0.64
Target exit safety factor3

Method & assumptions

  1. For steady one-dimensional flow, i = ΔH/L, v = ki and Q = vA. Average pore velocity is v/n with n = e/(1 + e).
  2. For an isotropic two-dimensional flow net, discharge per unit width is kΔH Nf/Nd. Count channels and potential drops as spaces between the drawn lines.
  3. The local upward exit gradient uses the final head drop ΔH/Nd divided by its spacing measured along the exiting streamline. The bulk Darcy gradient ΔH/L describes the full path.
  4. Use i꜀ᵣ = (Gs − 1)/(1 + e) and F.S. = i꜀ᵣ/iₑₓᵢₜ as a boiling screen for cohesionless exit soil. Check filters, internal erosion and field flow geometry separately.