Worked example
Equal head across a seepage section
Water levels are equal across the section in a steady-state snapshot.
Results
Edit inputs ↓- Darcy flow
- 0 m³/s
- Pore velocity
- 0 m/s
- Exit gradient
- 0
- Exit F.S.
- —
- Flow line
- Potential drop
- Exit cell
No head difference. Flow is zero and the exit safety factor is undefined.
Calculation details
| Average Darcy gradient ΔH/L | 0 |
|---|---|
| Darcy velocity | 0 m/s |
| Porosity from exit soil void ratio | 39 % |
| Flow-net discharge per unit width | 0 m²/s |
| Head loss per potential drop | 0 m |
| Critical upward gradient | 1.018 |
| Target maximum exit gradient | 0.339 |
GeotechSoilLab · Screening sheet · Metric SI
Equal head across a seepage section
| Head difference ΔH | 0 m |
|---|---|
| Seepage length L | 10 m |
| Hydraulic conductivity k | 1.80e-4 m/s |
| Cross-section A | 2.7 m² |
| Flow channels Nf | 4 |
| Potential drops Nd | 10 |
| Final drop spacing | 0.65 m |
| Solids specific gravity Gs | 2.67 |
| Exit soil void ratio e | 0.64 |
| Target exit safety factor | 3 |
| Darcy flow | 0 m³/s |
|---|---|
| Pore velocity | 0 m/s |
| Exit gradient | 0 |
| Exit F.S. | — |
| Average Darcy gradient ΔH/L | 0 |
| Darcy velocity | 0 m/s |
| Porosity from exit soil void ratio | 39 % |
| Flow-net discharge per unit width | 0 m²/s |
| Head loss per potential drop | 0 m |
| Critical upward gradient | 1.018 |
| Target maximum exit gradient | 0.339 |
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Worked result
Discharge and exit gradient are zero. The ratio of critical gradient to zero exit gradient is unavailable.
- Divide 0 m by 10 m for i = 0. Multiply ki by the section area to get Q = 0 m³/s.
- Use 4 flow channels and 10 potential drops for 0 m²/s per unit width.
- The final head drop is zero, so the exit-gradient ratio is undefined.
Darcy flow0 m³/sPore velocity0 m/sExit gradient0Exit F.S.—
Original case inputs
| Head difference ΔH | 0 m |
|---|---|
| Seepage length L | 10 m |
| Hydraulic conductivity k | 1.80e-4 m/s |
| Cross-section A | 2.7 m² |
| Flow channels Nf | 4 |
| Potential drops Nd | 10 |
| Final drop spacing | 0.65 m |
| Solids specific gravity Gs | 2.67 |
| Exit soil void ratio e | 0.64 |
| Target exit safety factor | 3 |
Method & assumptions
- For steady one-dimensional flow, i = ΔH/L, v = ki and Q = vA. Average pore velocity is v/n with n = e/(1 + e).
- For an isotropic two-dimensional flow net, discharge per unit width is kΔH Nf/Nd. Count channels and potential drops as spaces between the drawn lines.
- The local upward exit gradient uses the final head drop ΔH/Nd divided by its spacing measured along the exiting streamline. The bulk Darcy gradient ΔH/L describes the full path.
- Use i꜀ᵣ = (Gs − 1)/(1 + e) and F.S. = i꜀ᵣ/iₑₓᵢₜ as a boiling screen for cohesionless exit soil. Check filters, internal erosion and field flow geometry separately.
More worked examples
- Darcy flow through a sand columnA bench permeameter measures steady flow through a small sand cross-section.
- Flow net below a sheet pile cutoffAn illustrative two-dimensional flow net under a cutoff has five flow channels and fourteen potential drops.
- Upward exit near the boiling gradientAn upward exit through fine sand has a short last potential cell.
- Low-conductivity silt seepageA silty layer transmits a small steady discharge under a sustained head difference.
- Exit cell spacing and piping marginA filter study examines a relatively long spacing between the last equipotentials at the toe.