Pile & shaft axial capacity
Separate shaft friction, tip resistance and optional ENR or Modified Gates driving estimates.
Results
Edit inputs ↓- Allowable
- 271 kN
- Ultimate
- 677.4 kN
- Shaft
- 598.7 kN
- Tip
- 78.7 kN
- Shaft friction
- Tip bearing
- Embedment
Service compression is within the static allowable load.
Calculation details
| Allowable minus service load | 51 kN |
|---|---|
| Tip area | 0.159 m² |
| Shaft perimeter | 1.414 m |
| Mean unit shaft resistance | 30.3 kPa |
| Unit tip resistance | 495 kPa |
| Effective vertical stress at tip | — |
| Shaft share of static capacity | 88.4 % |
| Driving estimate basis | Off |
| End-of-drive screening load | — |
GeotechSoilLab · Screening sheet · Metric SI
Pile & shaft axial capacity
| Installation | Driven pile |
|---|---|
| Section shape | Round |
| Diameter or width | 0.45 m |
| Embedment L | 14 m |
| Static safety factor | 2.5 |
| Service axial load | 220 kN |
| Soil model | Clay (α) |
| Undrained strength su | 55 kPa |
| Adhesion factor α | 0.55 |
| Driving method | None |
| Allowable | 271 kN |
|---|---|
| Ultimate | 677.4 kN |
| Shaft | 598.7 kN |
| Tip | 78.7 kN |
| Allowable minus service load | 51 kN |
| Tip area | 0.159 m² |
| Shaft perimeter | 1.414 m |
| Mean unit shaft resistance | 30.3 kPa |
| Unit tip resistance | 495 kPa |
| Effective vertical stress at tip | — |
| Shaft share of static capacity | 88.4 % |
| Driving estimate basis | Off |
| End-of-drive screening load | — |
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Method & assumptions
- Clay uses unit shaft adhesion αsu and tip resistance 9su. Sand uses unit friction βσ′v and tip resistance Nq*σ′v. Shaft friction is integrated along the embedment and multiplied by section perimeter.
- The homogeneous sand model uses the effective unit weight to compute σ′v. A nonzero critical depth caps stress in both the shaft integral and tip term. The static allowable load is (Qs + Qp) / F.S.
- ENR divides input energy by the sum of set and empirical displacement, then by 6. The displacement is 0.1 in for a single-acting hammer and 1 in for a drop hammer.
- FHWA Modified Gates uses 1.75√E log₁₀(10N) − 100 kips with developed hammer energy E in ft·lbf and N in blows per inch. The coefficient includes the stated 80% efficiency convention. A nonpositive estimate is unavailable.
- The driving formulas apply to driven piles at end of drive. Select site-calibrated parameters for the installation method and verify load transfer, settlement and capacity with appropriate field testing.
Worked examples
- Driven circular pile in clayA driven circular pile extends through a uniform undrained clay profile.
- Driven square pile in sandA square pile extends through saturated uniform sand with no critical-depth cap.
- Sand pile with capped effective stressA critical-depth assumption limits the stress used below 14 m in a homogeneous sand screening model.
- Drilled shaft in cohesive soilA circular drilled shaft is screened using an installation-specific adhesion factor in clay.
- Drilled shaft in sandA drilled shaft bears in sand. The preliminary β and tip factors reflect the chosen construction method.
- ENR end-of-drive screeningA single-acting hammer records a set of 4.8 mm per blow at the end of driving.
- Modified Gates end-of-drive screeningA developed hammer energy and end-of-drive set are recorded for a driven steel pile.