Worked example
Modified Gates end-of-drive screening
A developed hammer energy and end-of-drive set are recorded for a driven steel pile.
Results
Edit inputs ↓- Allowable
- 132.3 kip
- Ultimate
- 330.8 kip
- Shaft
- 137.2 kip
- Tip
- 193.6 kip
- Shaft friction
- Tip bearing
- Embedment
Service compression is within the static allowable load. Modified Gates reports nominal end-of-drive resistance.
Calculation details
| Allowable minus service load | 82.9 kip |
|---|---|
| Tip area | 1.948 ft² |
| Shaft perimeter | 4.947 ft |
| Mean unit shaft resistance | 497.1 psf |
| Unit tip resistance | 99.415 ksf |
| Effective vertical stress at tip | 3,550.5 psf |
| Shaft share of static capacity | 41.5 % |
| Driving estimate basis | Gates nominal |
| End-of-drive screening load | 551.1 kip |
GeotechSoilLab · Screening sheet · US customary
Modified Gates end-of-drive screening
| Installation | Driven pile |
|---|---|
| Section shape | Round |
| Diameter or width | 1.5748 ft |
| Embedment L | 55.77428 ft |
| Static safety factor | 2.5 |
| Service axial load | 49.45797 kip |
| Soil model | Sand (β) |
| Shaft factor β | 0.28 |
| Effective weight γ′ | 63.6588 pcf |
| Tip factor Nq* | 28 |
| Critical depth | 0 ft |
| Driving method | Modified Gates |
| Hammer energy E | 38.35323 kip·ft |
| Set per blow | 0.12598 in |
| Allowable | 132.3 kip |
|---|---|
| Ultimate | 330.8 kip |
| Shaft | 137.2 kip |
| Tip | 193.6 kip |
| Allowable minus service load | 82.9 kip |
| Tip area | 1.948 ft² |
| Shaft perimeter | 4.947 ft |
| Mean unit shaft resistance | 497.1 psf |
| Unit tip resistance | 99.415 ksf |
| Effective vertical stress at tip | 3,550.5 psf |
| Shaft share of static capacity | 41.5 % |
| Driving estimate basis | Gates nominal |
| End-of-drive screening load | 551.1 kip |
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Worked result
Convert set to blows per inch and energy to ft·lbf before applying the FHWA Modified Gates equation. Its result is nominal resistance.
- A mean shaft stress of 497.073 psf gives Qs = 137.161 kip. Tip stress times 1.948 ft² gives Qp = 193.639 kip.
- Add Qs and Qp to get 330.8 kip. Divide by 2.5 for a static allowable load of 132.32 kip.
- The Gates nominal end-of-drive result is 551.059 kip.
Allowable132.3 kipUltimate330.8 kipShaft137.2 kipTip193.6 kip
Original case inputs
| Installation | Driven pile |
|---|---|
| Section shape | Round |
| Diameter or width | 1.5748 ft |
| Embedment L | 55.77428 ft |
| Static safety factor | 2.5 |
| Service axial load | 49.45797 kip |
| Soil model | Sand (β) |
| Shaft factor β | 0.28 |
| Effective weight γ′ | 63.6588 pcf |
| Tip factor Nq* | 28 |
| Critical depth | 0 ft |
| Driving method | Modified Gates |
| Hammer energy E | 38.35323 kip·ft |
| Set per blow | 0.12598 in |
Method & assumptions
- Clay uses unit shaft adhesion αsu and tip resistance 9su. Sand uses unit friction βσ′v and tip resistance Nq*σ′v. Shaft friction is integrated along the embedment and multiplied by section perimeter.
- The homogeneous sand model uses the effective unit weight to compute σ′v. A nonzero critical depth caps stress in both the shaft integral and tip term. The static allowable load is (Qs + Qp) / F.S.
- ENR divides input energy by the sum of set and empirical displacement, then by 6. The displacement is 0.1 in for a single-acting hammer and 1 in for a drop hammer.
- FHWA Modified Gates uses 1.75√E log₁₀(10N) − 100 kips with developed hammer energy E in ft·lbf and N in blows per inch. The coefficient includes the stated 80% efficiency convention. A nonpositive estimate is unavailable.
- The driving formulas apply to driven piles at end of drive. Select site-calibrated parameters for the installation method and verify load transfer, settlement and capacity with appropriate field testing.
More worked examples
- Driven circular pile in clayA driven circular pile extends through a uniform undrained clay profile.
- Driven square pile in sandA square pile extends through saturated uniform sand with no critical-depth cap.
- Sand pile with capped effective stressA critical-depth assumption limits the stress used below 14 m in a homogeneous sand screening model.
- Drilled shaft in cohesive soilA circular drilled shaft is screened using an installation-specific adhesion factor in clay.
- Drilled shaft in sandA drilled shaft bears in sand. The preliminary β and tip factors reflect the chosen construction method.
- ENR end-of-drive screeningA single-acting hammer records a set of 4.8 mm per blow at the end of driving.