Worked example

Drilled shaft in cohesive soil

A circular drilled shaft is screened using an installation-specific adhesion factor in clay.

Allowable
943.4 kN
Ultimate
2,830.2 kN
Shaft
2,243.3 kN
Tip
586.9 kN
Shaft friction & tip resistance Schematic
Shaft friction & tip resistance, schematic ShaftTipClay · α methodStatic load transferL 19 mShaft 79.3%Service / allowable23.3%
  • Shaft friction
  • Tip bearing
  • Embedment

Service compression is within the static allowable load. Select installation-appropriate shaft and tip parameters for the drilled shaft.

Calculation details
Allowable minus service load723.4 kN
Tip area0.709 m²
Shaft perimeter2.985 m
Mean unit shaft resistance39.6 kPa
Unit tip resistance828 kPa
Effective vertical stress at tip—
Shaft share of static capacity79.3 %
Driving estimate basisOff
End-of-drive screening load—

Inputs

Pile or shaft geometry
Shaft and tip resistance

Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.

Worked result

The larger diameter changes the balance of tip and shaft resistance. Use load test or local calibration for the adopted factor.

  1. A mean shaft stress of 39.56 kPa gives Qs = 2,243.279 kN. Tip stress times 0.709 m² gives Qp = 586.904 kN.
  2. Add Qs and Qp to get 2,830.184 kN. Divide by 3 for a static allowable load of 943.395 kN.
Allowable943.4 kNUltimate2,830.2 kNShaft2,243.3 kNTip586.9 kN
Original case inputs
InstallationDrilled shaft
Section shapeRound
Diameter or width0.95 m
Embedment L19 m
Static safety factor3
Service axial load220 kN
Soil modelClay (α)
Undrained strength su92 kPa
Adhesion factor α0.43

Method & assumptions

  1. Clay uses unit shaft adhesion αsu and tip resistance 9su. Sand uses unit friction βσ′v and tip resistance Nq*σ′v. Shaft friction is integrated along the embedment and multiplied by section perimeter.
  2. The homogeneous sand model uses the effective unit weight to compute σ′v. A nonzero critical depth caps stress in both the shaft integral and tip term. The static allowable load is (Qs + Qp) / F.S.
  3. ENR divides input energy by the sum of set and empirical displacement, then by 6. The displacement is 0.1 in for a single-acting hammer and 1 in for a drop hammer.
  4. FHWA Modified Gates uses 1.75√E log₁₀(10N) − 100 kips with developed hammer energy E in ft·lbf and N in blows per inch. The coefficient includes the stated 80% efficiency convention. A nonpositive estimate is unavailable.
  5. The driving formulas apply to driven piles at end of drive. Select site-calibrated parameters for the installation method and verify load transfer, settlement and capacity with appropriate field testing.