Worked example
Driven square pile in sand
A square pile extends through saturated uniform sand with no critical-depth cap.
Results
Edit inputs ↓- Allowable
- 88.8 kip
- Ultimate
- 222 kip
- Shaft
- 94.8 kip
- Tip
- 127.3 kip
- Shaft friction
- Tip bearing
- Embedment
Service compression is within the static allowable load.
Calculation details
| Allowable minus service load | 39.4 kip |
|---|---|
| Tip area | 1.395 ft² |
| Shaft perimeter | 4.724 ft |
| Mean unit shaft resistance | 470.4 psf |
| Unit tip resistance | 91.228 ksf |
| Effective vertical stress at tip | 2,850.9 psf |
| Shaft share of static capacity | 42.7 % |
| Driving estimate basis | Off |
| End-of-drive screening load | — |
GeotechSoilLab · Screening sheet · US customary
Driven square pile in sand
| Installation | Driven pile |
|---|---|
| Section shape | Square |
| Diameter or width | 1.1811 ft |
| Embedment L | 42.65092 ft |
| Static safety factor | 2.5 |
| Service axial load | 49.45797 kip |
| Soil model | Sand (β) |
| Shaft factor β | 0.33 |
| Effective weight γ′ | 66.84174 pcf |
| Tip factor Nq* | 32 |
| Critical depth | 0 ft |
| Driving method | None |
| Allowable | 88.8 kip |
|---|---|
| Ultimate | 222 kip |
| Shaft | 94.8 kip |
| Tip | 127.3 kip |
| Allowable minus service load | 39.4 kip |
| Tip area | 1.395 ft² |
| Shaft perimeter | 4.724 ft |
| Mean unit shaft resistance | 470.4 psf |
| Unit tip resistance | 91.228 ksf |
| Effective vertical stress at tip | 2,850.9 psf |
| Shaft share of static capacity | 42.7 % |
| Driving estimate basis | Off |
| End-of-drive screening load | — |
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Worked result
Effective stress increases linearly. Average shaft stress uses one-half the tip-depth overburden before applying β.
- A mean shaft stress of 470.392 psf gives Qs = 94.784 kip. Tip stress times 1.395 ft² gives Qp = 127.263 kip.
- Add Qs and Qp to get 222.047 kip. Divide by 2.5 for a static allowable load of 88.819 kip.
Allowable88.8 kipUltimate222 kipShaft94.8 kipTip127.3 kip
Original case inputs
| Installation | Driven pile |
|---|---|
| Section shape | Square |
| Diameter or width | 1.1811 ft |
| Embedment L | 42.65092 ft |
| Static safety factor | 2.5 |
| Service axial load | 49.45797 kip |
| Soil model | Sand (β) |
| Shaft factor β | 0.33 |
| Effective weight γ′ | 66.84174 pcf |
| Tip factor Nq* | 32 |
| Critical depth | 0 ft |
| Driving method | None |
Method & assumptions
- Clay uses unit shaft adhesion αsu and tip resistance 9su. Sand uses unit friction βσ′v and tip resistance Nq*σ′v. Shaft friction is integrated along the embedment and multiplied by section perimeter.
- The homogeneous sand model uses the effective unit weight to compute σ′v. A nonzero critical depth caps stress in both the shaft integral and tip term. The static allowable load is (Qs + Qp) / F.S.
- ENR divides input energy by the sum of set and empirical displacement, then by 6. The displacement is 0.1 in for a single-acting hammer and 1 in for a drop hammer.
- FHWA Modified Gates uses 1.75√E log₁₀(10N) − 100 kips with developed hammer energy E in ft·lbf and N in blows per inch. The coefficient includes the stated 80% efficiency convention. A nonpositive estimate is unavailable.
- The driving formulas apply to driven piles at end of drive. Select site-calibrated parameters for the installation method and verify load transfer, settlement and capacity with appropriate field testing.
More worked examples
- Driven circular pile in clayA driven circular pile extends through a uniform undrained clay profile.
- Sand pile with capped effective stressA critical-depth assumption limits the stress used below 14 m in a homogeneous sand screening model.
- Drilled shaft in cohesive soilA circular drilled shaft is screened using an installation-specific adhesion factor in clay.
- Drilled shaft in sandA drilled shaft bears in sand. The preliminary β and tip factors reflect the chosen construction method.
- ENR end-of-drive screeningA single-acting hammer records a set of 4.8 mm per blow at the end of driving.
- Modified Gates end-of-drive screeningA developed hammer energy and end-of-drive set are recorded for a driven steel pile.