Worked example

Driven square pile in sand

A square pile extends through saturated uniform sand with no critical-depth cap.

Allowable
88.8 kip
Ultimate
222 kip
Shaft
94.8 kip
Tip
127.3 kip
Shaft friction & tip resistance Schematic
Shaft friction & tip resistance, schematic ShaftTipSand · β methodStatic load transferL 42.65 ftShaft 42.7%Service / allowable55.7%
  • Shaft friction
  • Tip bearing
  • Embedment

Service compression is within the static allowable load.

Calculation details
Allowable minus service load39.4 kip
Tip area1.395 ft²
Shaft perimeter4.724 ft
Mean unit shaft resistance470.4 psf
Unit tip resistance91.228 ksf
Effective vertical stress at tip2,850.9 psf
Shaft share of static capacity42.7 %
Driving estimate basisOff
End-of-drive screening load—

Inputs

Pile or shaft geometry
Shaft and tip resistance
Zero leaves the effective stress uncapped.
End-of-drive screening

Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.

Worked result

Effective stress increases linearly. Average shaft stress uses one-half the tip-depth overburden before applying β.

  1. A mean shaft stress of 470.392 psf gives Qs = 94.784 kip. Tip stress times 1.395 ft² gives Qp = 127.263 kip.
  2. Add Qs and Qp to get 222.047 kip. Divide by 2.5 for a static allowable load of 88.819 kip.
Allowable88.8 kipUltimate222 kipShaft94.8 kipTip127.3 kip
Original case inputs
InstallationDriven pile
Section shapeSquare
Diameter or width1.1811 ft
Embedment L42.65092 ft
Static safety factor2.5
Service axial load49.45797 kip
Soil modelSand (β)
Shaft factor β0.33
Effective weight γ′66.84174 pcf
Tip factor Nq*32
Critical depth0 ft
Driving methodNone

Method & assumptions

  1. Clay uses unit shaft adhesion αsu and tip resistance 9su. Sand uses unit friction βσ′v and tip resistance Nq*σ′v. Shaft friction is integrated along the embedment and multiplied by section perimeter.
  2. The homogeneous sand model uses the effective unit weight to compute σ′v. A nonzero critical depth caps stress in both the shaft integral and tip term. The static allowable load is (Qs + Qp) / F.S.
  3. ENR divides input energy by the sum of set and empirical displacement, then by 6. The displacement is 0.1 in for a single-acting hammer and 1 in for a drop hammer.
  4. FHWA Modified Gates uses 1.75√E log₁₀(10N) − 100 kips with developed hammer energy E in ft·lbf and N in blows per inch. The coefficient includes the stated 80% efficiency convention. A nonpositive estimate is unavailable.
  5. The driving formulas apply to driven piles at end of drive. Select site-calibrated parameters for the installation method and verify load transfer, settlement and capacity with appropriate field testing.

More worked examples