Pile & shaft axial capacity

Separate shaft friction, tip resistance and optional ENR or Modified Gates driving estimates.

Allowable
271 kN
Ultimate
677.4 kN
Shaft
598.7 kN
Tip
78.7 kN
Shaft friction & tip resistance Schematic
Shaft friction & tip resistance, schematic ShaftTipClay · α methodStatic load transferL 14 mShaft 88.4%Service / allowable81.2%
  • Shaft friction
  • Tip bearing
  • Embedment

Service compression is within the static allowable load.

Calculation details
Allowable minus service load51 kN
Tip area0.159 m²
Shaft perimeter1.414 m
Mean unit shaft resistance30.3 kPa
Unit tip resistance495 kPa
Effective vertical stress at tip—
Shaft share of static capacity88.4 %
Driving estimate basisOff
End-of-drive screening load—

Inputs

Pile or shaft geometry
Shaft and tip resistance
End-of-drive screening

Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.

Method & assumptions

  1. Clay uses unit shaft adhesion αsu and tip resistance 9su. Sand uses unit friction βσ′v and tip resistance Nq*σ′v. Shaft friction is integrated along the embedment and multiplied by section perimeter.
  2. The homogeneous sand model uses the effective unit weight to compute σ′v. A nonzero critical depth caps stress in both the shaft integral and tip term. The static allowable load is (Qs + Qp) / F.S.
  3. ENR divides input energy by the sum of set and empirical displacement, then by 6. The displacement is 0.1 in for a single-acting hammer and 1 in for a drop hammer.
  4. FHWA Modified Gates uses 1.75√E log₁₀(10N) − 100 kips with developed hammer energy E in ft·lbf and N in blows per inch. The coefficient includes the stated 80% efficiency convention. A nonpositive estimate is unavailable.
  5. The driving formulas apply to driven piles at end of drive. Select site-calibrated parameters for the installation method and verify load transfer, settlement and capacity with appropriate field testing.

Worked examples