Worked example
Rankine wall with level backfill
A short cantilever wall supports a level landscape fill without a surface surcharge.
Results
Edit inputs ↓- Active thrust
- 23.54 kN/m
- Sliding F.S.
- 2.66
- Overturn F.S.
- 5.99
- Eccentricity
- 0.001 m
- Active pressure
- Surcharge
- Resultant
Sliding, overturning and middle-third screens all meet the displayed limits.
Calculation details
| Active coefficient Ka | 0.283 |
|---|---|
| Reference passive Kp (smooth, level toe) | 3.537 |
| Effective retained height at heel | 3 m |
| Total horizontal driving force | 23.54 kN/m |
| Downward active force | 0 kN/m |
| Thrust height above base top | 1 m |
| Horizontal water thrust | 0 kN/m |
| Base uplift | 0 kN/m |
| Base width B | 2.48 m |
| Middle-third eccentricity limit B/6 | 0.413 m |
| Base resultant from toe | 1.239 m |
| Toe bearing pressure | 50.6 kPa |
| Heel bearing pressure | 50.4 kPa |
| Maximum contact pressure | 50.6 kPa |
| Minimum contact pressure | 50.4 kPa |
| Compression contact width | 2.48 m |
| Concrete stem weight | 20.16 kN/m |
| Concrete base weight | 19.05 kN/m |
| Soil weight over heel | 86.03 kN/m |
| Net downward load | 125.23 kN/m |
| Resisting moment about toe | 186.22 kN·m/m |
| Driving moment about toe | 31.07 kN·m/m |
GeotechSoilLab · Screening sheet · Metric SI
Rankine wall with level backfill
| Stem height H | 3 m |
|---|---|
| Stem thickness | 0.28 m |
| Toe projection | 0.65 m |
| Heel projection | 1.55 m |
| Base thickness | 0.32 m |
| Concrete weight | 24 kN/m³ |
| Pressure method | Rankine |
| Friction angle φ′ | 34 ° |
| Backfill slope β | 0 ° |
| Backfill weight γ | 18.5 kN/m³ |
| Uniform surcharge q | 0 kPa |
| Base friction μ | 0.5 |
| Backfill water | Drained |
| Active thrust | 23.54 kN/m |
|---|---|
| Sliding F.S. | 2.66 |
| Overturn F.S. | 5.99 |
| Eccentricity | 0.001 m |
| Active coefficient Ka | 0.283 |
| Reference passive Kp (smooth, level toe) | 3.537 |
| Effective retained height at heel | 3 m |
| Total horizontal driving force | 23.54 kN/m |
| Downward active force | 0 kN/m |
| Thrust height above base top | 1 m |
| Horizontal water thrust | 0 kN/m |
| Base uplift | 0 kN/m |
| Base width B | 2.48 m |
| Middle-third eccentricity limit B/6 | 0.413 m |
| Base resultant from toe | 1.239 m |
| Toe bearing pressure | 50.6 kPa |
| Heel bearing pressure | 50.4 kPa |
| Maximum contact pressure | 50.6 kPa |
| Minimum contact pressure | 50.4 kPa |
| Compression contact width | 2.48 m |
| Concrete stem weight | 20.16 kN/m |
| Concrete base weight | 19.05 kN/m |
| Soil weight over heel | 86.03 kN/m |
| Net downward load | 125.23 kN/m |
| Resisting moment about toe | 186.22 kN·m/m |
| Driving moment about toe | 31.07 kN·m/m |
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Worked result
With triangular soil pressure only, the resultant acts at one-third of the retained height above the top of the base.
- Use Kₐ = 0.2827 over a retained height of 3 m. The active thrust is 23.536 kN/m at 1 m above the base top.
- Base friction times the downward load divided by horizontal thrust gives a sliding F.S. of 2.66. Dividing 186.217 kN·m/m by 31.068 kN·m/m gives an overturning F.S. of 5.994.
- Compare the absolute eccentricity of 0.001 m with B/6 = 0.413 m.
Active thrust23.54 kN/mSliding F.S.2.66Overturn F.S.5.99Eccentricity0.001 m
Original case inputs
| Stem height H | 3 m |
|---|---|
| Stem thickness | 0.28 m |
| Toe projection | 0.65 m |
| Heel projection | 1.55 m |
| Base thickness | 0.32 m |
| Concrete weight | 24 kN/m³ |
| Pressure method | Rankine |
| Friction angle φ′ | 34 ° |
| Backfill slope β | 0 ° |
| Backfill weight γ | 18.5 kN/m³ |
| Uniform surcharge q | 0 kPa |
| Base friction μ | 0.5 |
| Backfill water | Drained |
Method & assumptions
- Model the concrete and soil over the heel as a single gravity block. Apply active pressure on a vertical plane at the heel, where retained height is H + heel × tan β.
- For dry backfill, Pa = Ka(½γH² + qH) using the effective height at the heel. Soil thrust acts at one-third height and surcharge thrust at half height. Rankine inclines down by β. Coulomb uses the equivalent angle δ on the assumed heel plane.
- The reference Kp assumes level ground and a smooth passive plane. Water reduces effective soil pressure below its level and adds a separate horizontal hydrostatic triangle. The wet screen assumes no water in front and applies full heel water pressure uniformly under the base.
- Sliding F.S. = μV / Ph. Overturning F.S. is the ratio of resisting to driving moment about the toe. Positive eccentricity is toward the toe. Full contact uses V/B(1 ± 6e/B). Beyond the middle third, the base uses a compression-only triangle where a resultant remains within the base.
- Illustrative limits are 1.50 sliding and 2.00 overturning. Count base friction on net normal load, with zero passive resistance credit. Check site-specific bearing, global stability and the actual groundwater and uplift distribution.
More worked examples
- Retaining wall with traffic surchargeAn adjacent traffic area is approximated by a uniform 22 kPa surcharge.
- Rankine wall with a sloping backfillA landscaped backfill rises away from the retaining stem at 15°.
- Coulomb wall with interface frictionA preliminary gravity-block check uses a Coulomb interface angle of 16° and slightly rising backfill.
- Retaining wall with partial base contactA narrow base under surcharge is used to illustrate the transition from full to partial soil contact.
- Retaining wall with resultant beyond the toeAn intentionally undersized section demonstrates a failed equilibrium screen.