Worked example

Rankine wall with level backfill

A short cantilever wall supports a level landscape fill without a surface surcharge.

Active thrust
23.54 kN/m
Sliding F.S.
2.66
Overturn F.S.
5.99
Eccentricity
0.001 m
Wall section & lateral pressure Schematic
Wall section & lateral pressure, schematic Backfill 0°Lateral pressureBase 2.48 mPₐ 23.54 kN/mGoverning limit ratio177.4%
  • Active pressure
  • Surcharge
  • Resultant

Sliding, overturning and middle-third screens all meet the displayed limits.

Calculation details
Active coefficient Ka0.283
Reference passive Kp (smooth, level toe)3.537
Effective retained height at heel3 m
Total horizontal driving force23.54 kN/m
Downward active force0 kN/m
Thrust height above base top1 m
Horizontal water thrust0 kN/m
Base uplift0 kN/m
Base width B2.48 m
Middle-third eccentricity limit B/60.413 m
Base resultant from toe1.239 m
Toe bearing pressure50.6 kPa
Heel bearing pressure50.4 kPa
Maximum contact pressure50.6 kPa
Minimum contact pressure50.4 kPa
Compression contact width2.48 m
Concrete stem weight20.16 kN/m
Concrete base weight19.05 kN/m
Soil weight over heel86.03 kN/m
Net downward load125.23 kN/m
Resisting moment about toe186.22 kN·m/m
Driving moment about toe31.07 kN·m/m

Inputs

Wall section
Backfill and interface
Groundwater behind wall

Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.

Worked result

With triangular soil pressure only, the resultant acts at one-third of the retained height above the top of the base.

  1. Use Kₐ = 0.2827 over a retained height of 3 m. The active thrust is 23.536 kN/m at 1 m above the base top.
  2. Base friction times the downward load divided by horizontal thrust gives a sliding F.S. of 2.66. Dividing 186.217 kN·m/m by 31.068 kN·m/m gives an overturning F.S. of 5.994.
  3. Compare the absolute eccentricity of 0.001 m with B/6 = 0.413 m.
Active thrust23.54 kN/mSliding F.S.2.66Overturn F.S.5.99Eccentricity0.001 m
Original case inputs
Stem height H3 m
Stem thickness0.28 m
Toe projection0.65 m
Heel projection1.55 m
Base thickness0.32 m
Concrete weight24 kN/m³
Pressure methodRankine
Friction angle φ′34 °
Backfill slope β0 °
Backfill weight γ18.5 kN/m³
Uniform surcharge q0 kPa
Base friction μ0.5
Backfill waterDrained

Method & assumptions

  1. Model the concrete and soil over the heel as a single gravity block. Apply active pressure on a vertical plane at the heel, where retained height is H + heel × tan β.
  2. For dry backfill, Pa = Ka(½γH² + qH) using the effective height at the heel. Soil thrust acts at one-third height and surcharge thrust at half height. Rankine inclines down by β. Coulomb uses the equivalent angle δ on the assumed heel plane.
  3. The reference Kp assumes level ground and a smooth passive plane. Water reduces effective soil pressure below its level and adds a separate horizontal hydrostatic triangle. The wet screen assumes no water in front and applies full heel water pressure uniformly under the base.
  4. Sliding F.S. = μV / Ph. Overturning F.S. is the ratio of resisting to driving moment about the toe. Positive eccentricity is toward the toe. Full contact uses V/B(1 ± 6e/B). Beyond the middle third, the base uses a compression-only triangle where a resultant remains within the base.
  5. Illustrative limits are 1.50 sliding and 2.00 overturning. Count base friction on net normal load, with zero passive resistance credit. Check site-specific bearing, global stability and the actual groundwater and uplift distribution.

More worked examples