Worked example

Retaining wall with traffic surcharge

An adjacent traffic area is approximated by a uniform 22 kPa surcharge.

Active thrust
4.02 kip/ft
Sliding F.S.
1.41
Overturn F.S.
2.36
Eccentricity
1.359 ft
Wall section & lateral pressure Schematic
Wall section & lateral pressure, schematic Backfill 0°Lateral pressureBase 8.69 ftPₐ 4.02 kip/ftGoverning limit ratio94%
  • Active pressure
  • Surcharge
  • Resultant

One or more stability screens fall below the displayed limits.

Calculation details
Active coefficient Ka0.295
Reference passive Kp (smooth, level toe)3.392
Effective retained height at heel11.81 ft
Total horizontal driving force4.02 kip/ft
Downward active force0 kip/ft
Thrust height above base top4.72 ft
Horizontal water thrust0 kip/ft
Base uplift0 kip/ft
Base width B8.69 ft
Middle-third eccentricity limit B/61.449 ft
Base resultant from toe2.988 ft
Toe bearing pressure2.526 ksf
Heel bearing pressure0.081 ksf
Maximum contact pressure2.526 ksf
Minimum contact pressure0.081 ksf
Compression contact width8.694 ft
Concrete stem weight2.07 kip/ft
Concrete base weight1.96 kip/ft
Soil weight over heel7.3 kip/ft
Net downward load11.33 kip/ft
Resisting moment about toe58.79 kip·ft/ft
Driving moment about toe24.92 kip·ft/ft

Inputs

Wall section
Backfill and interface
Groundwater behind wall

Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.

Worked result

The rectangular surcharge pressure raises the combined force and shifts it above the soil triangle’s centroid.

  1. Use Kₐ = 0.2948 over a retained height of 11.811 ft. The active thrust is 4.021 kip/ft at 4.72 ft above the base top.
  2. Base friction times the downward load divided by horizontal thrust gives a sliding F.S. of 1.409. Dividing 58.791 kip·ft/ft by 24.919 kip·ft/ft gives an overturning F.S. of 2.359.
  3. Compare the absolute eccentricity of 1.359 ft with B/6 = 1.449 ft.
Active thrust4.02 kip/ftSliding F.S.1.41Overturn F.S.2.36Eccentricity1.359 ft
Original case inputs
Stem height H11.81102 ft
Stem thickness1.14829 ft
Toe projection2.29659 ft
Heel projection5.24934 ft
Base thickness1.47638 ft
Concrete weight152.78113 pcf
Pressure methodRankine
Friction angle φ′33 °
Backfill slope β0 °
Backfill weight γ117.76879 pcf
Uniform surcharge q459.47955 psf
Base friction μ0.5
Backfill waterDrained

Method & assumptions

  1. Model the concrete and soil over the heel as a single gravity block. Apply active pressure on a vertical plane at the heel, where retained height is H + heel × tan β.
  2. For dry backfill, Pa = Ka(½γH² + qH) using the effective height at the heel. Soil thrust acts at one-third height and surcharge thrust at half height. Rankine inclines down by β. Coulomb uses the equivalent angle δ on the assumed heel plane.
  3. The reference Kp assumes level ground and a smooth passive plane. Water reduces effective soil pressure below its level and adds a separate horizontal hydrostatic triangle. The wet screen assumes no water in front and applies full heel water pressure uniformly under the base.
  4. Sliding F.S. = μV / Ph. Overturning F.S. is the ratio of resisting to driving moment about the toe. Positive eccentricity is toward the toe. Full contact uses V/B(1 ± 6e/B). Beyond the middle third, the base uses a compression-only triangle where a resultant remains within the base.
  5. Illustrative limits are 1.50 sliding and 2.00 overturning. Count base friction on net normal load, with zero passive resistance credit. Check site-specific bearing, global stability and the actual groundwater and uplift distribution.