Worked example
Retaining wall with traffic surcharge
An adjacent traffic area is approximated by a uniform 22 kPa surcharge.
Results
Edit inputs ↓- Active thrust
- 4.02 kip/ft
- Sliding F.S.
- 1.41
- Overturn F.S.
- 2.36
- Eccentricity
- 1.359 ft
- Active pressure
- Surcharge
- Resultant
One or more stability screens fall below the displayed limits.
Calculation details
| Active coefficient Ka | 0.295 |
|---|---|
| Reference passive Kp (smooth, level toe) | 3.392 |
| Effective retained height at heel | 11.81 ft |
| Total horizontal driving force | 4.02 kip/ft |
| Downward active force | 0 kip/ft |
| Thrust height above base top | 4.72 ft |
| Horizontal water thrust | 0 kip/ft |
| Base uplift | 0 kip/ft |
| Base width B | 8.69 ft |
| Middle-third eccentricity limit B/6 | 1.449 ft |
| Base resultant from toe | 2.988 ft |
| Toe bearing pressure | 2.526 ksf |
| Heel bearing pressure | 0.081 ksf |
| Maximum contact pressure | 2.526 ksf |
| Minimum contact pressure | 0.081 ksf |
| Compression contact width | 8.694 ft |
| Concrete stem weight | 2.07 kip/ft |
| Concrete base weight | 1.96 kip/ft |
| Soil weight over heel | 7.3 kip/ft |
| Net downward load | 11.33 kip/ft |
| Resisting moment about toe | 58.79 kip·ft/ft |
| Driving moment about toe | 24.92 kip·ft/ft |
GeotechSoilLab · Screening sheet · US customary
Retaining wall with traffic surcharge
| Stem height H | 11.81102 ft |
|---|---|
| Stem thickness | 1.14829 ft |
| Toe projection | 2.29659 ft |
| Heel projection | 5.24934 ft |
| Base thickness | 1.47638 ft |
| Concrete weight | 152.78113 pcf |
| Pressure method | Rankine |
| Friction angle φ′ | 33 ° |
| Backfill slope β | 0 ° |
| Backfill weight γ | 117.76879 pcf |
| Uniform surcharge q | 459.47955 psf |
| Base friction μ | 0.5 |
| Backfill water | Drained |
| Active thrust | 4.02 kip/ft |
|---|---|
| Sliding F.S. | 1.41 |
| Overturn F.S. | 2.36 |
| Eccentricity | 1.359 ft |
| Active coefficient Ka | 0.295 |
| Reference passive Kp (smooth, level toe) | 3.392 |
| Effective retained height at heel | 11.81 ft |
| Total horizontal driving force | 4.02 kip/ft |
| Downward active force | 0 kip/ft |
| Thrust height above base top | 4.72 ft |
| Horizontal water thrust | 0 kip/ft |
| Base uplift | 0 kip/ft |
| Base width B | 8.69 ft |
| Middle-third eccentricity limit B/6 | 1.449 ft |
| Base resultant from toe | 2.988 ft |
| Toe bearing pressure | 2.526 ksf |
| Heel bearing pressure | 0.081 ksf |
| Maximum contact pressure | 2.526 ksf |
| Minimum contact pressure | 0.081 ksf |
| Compression contact width | 8.694 ft |
| Concrete stem weight | 2.07 kip/ft |
| Concrete base weight | 1.96 kip/ft |
| Soil weight over heel | 7.3 kip/ft |
| Net downward load | 11.33 kip/ft |
| Resisting moment about toe | 58.79 kip·ft/ft |
| Driving moment about toe | 24.92 kip·ft/ft |
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Worked result
The rectangular surcharge pressure raises the combined force and shifts it above the soil triangle’s centroid.
- Use Kₐ = 0.2948 over a retained height of 11.811 ft. The active thrust is 4.021 kip/ft at 4.72 ft above the base top.
- Base friction times the downward load divided by horizontal thrust gives a sliding F.S. of 1.409. Dividing 58.791 kip·ft/ft by 24.919 kip·ft/ft gives an overturning F.S. of 2.359.
- Compare the absolute eccentricity of 1.359 ft with B/6 = 1.449 ft.
Active thrust4.02 kip/ftSliding F.S.1.41Overturn F.S.2.36Eccentricity1.359 ft
Original case inputs
| Stem height H | 11.81102 ft |
|---|---|
| Stem thickness | 1.14829 ft |
| Toe projection | 2.29659 ft |
| Heel projection | 5.24934 ft |
| Base thickness | 1.47638 ft |
| Concrete weight | 152.78113 pcf |
| Pressure method | Rankine |
| Friction angle φ′ | 33 ° |
| Backfill slope β | 0 ° |
| Backfill weight γ | 117.76879 pcf |
| Uniform surcharge q | 459.47955 psf |
| Base friction μ | 0.5 |
| Backfill water | Drained |
Method & assumptions
- Model the concrete and soil over the heel as a single gravity block. Apply active pressure on a vertical plane at the heel, where retained height is H + heel × tan β.
- For dry backfill, Pa = Ka(½γH² + qH) using the effective height at the heel. Soil thrust acts at one-third height and surcharge thrust at half height. Rankine inclines down by β. Coulomb uses the equivalent angle δ on the assumed heel plane.
- The reference Kp assumes level ground and a smooth passive plane. Water reduces effective soil pressure below its level and adds a separate horizontal hydrostatic triangle. The wet screen assumes no water in front and applies full heel water pressure uniformly under the base.
- Sliding F.S. = μV / Ph. Overturning F.S. is the ratio of resisting to driving moment about the toe. Positive eccentricity is toward the toe. Full contact uses V/B(1 ± 6e/B). Beyond the middle third, the base uses a compression-only triangle where a resultant remains within the base.
- Illustrative limits are 1.50 sliding and 2.00 overturning. Count base friction on net normal load, with zero passive resistance credit. Check site-specific bearing, global stability and the actual groundwater and uplift distribution.
More worked examples
- Rankine wall with level backfillA short cantilever wall supports a level landscape fill without a surface surcharge.
- Rankine wall with a sloping backfillA landscaped backfill rises away from the retaining stem at 15°.
- Coulomb wall with interface frictionA preliminary gravity-block check uses a Coulomb interface angle of 16° and slightly rising backfill.
- Retaining wall with partial base contactA narrow base under surcharge is used to illustrate the transition from full to partial soil contact.
- Retaining wall with resultant beyond the toeAn intentionally undersized section demonstrates a failed equilibrium screen.