Worked example

Retaining wall with resultant beyond the toe

An intentionally undersized section demonstrates a failed equilibrium screen.

Active thrust
172.21 kN/m
Sliding F.S.
0.26
Overturn F.S.
0.17
Eccentricity
3.867 m
Wall section & lateral pressure Schematic
Wall section & lateral pressure, schematic Backfill 0°Lateral pressureBase 1.15 mPₐ 172.21 kN/mGoverning limit ratio5%
  • Active pressure
  • Surcharge
  • Resultant

One or more stability screens fall below the displayed limits. The base resultant falls outside the footing. Bearing pressures are unavailable.

Calculation details
Active coefficient Ka0.361
Reference passive Kp (smooth, level toe)2.77
Effective retained height at heel6 m
Total horizontal driving force172.21 kN/m
Downward active force0 kN/m
Thrust height above base top2.3 m
Horizontal water thrust0 kN/m
Base uplift0 kN/m
Base width B1.15 m
Middle-third eccentricity limit B/60.192 m
Base resultant from toe-3.292 m
Toe bearing pressure—
Heel bearing pressure—
Maximum contact pressure—
Minimum contact pressure—
Compression contact width—
Concrete stem weight43.2 kN/m
Concrete base weight8.28 kN/m
Soil weight over heel61.05 kN/m
Net downward load112.53 kN/m
Resisting moment about toe77.62 kN·m/m
Driving moment about toe448.08 kN·m/m

Inputs

Wall section
Backfill and interface
Groundwater behind wall

Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.

Worked result

The resultant falls outside the base so the model cannot report toe or heel contact pressure.

  1. Use Kₐ = 0.361 over a retained height of 6 m. The active thrust is 172.213 kN/m at 2.302 m above the base top.
  2. Base friction times the downward load divided by horizontal thrust gives a sliding F.S. of 0.261. Dividing 77.62 kN·m/m by 448.079 kN·m/m gives an overturning F.S. of 0.173.
  3. Compare the absolute eccentricity of 3.867 m with B/6 = 0.192 m.
Active thrust172.21 kN/mSliding F.S.0.26Overturn F.S.0.17Eccentricity3.867 m
Original case inputs
Stem height H6 m
Stem thickness0.3 m
Toe projection0.3 m
Heel projection0.55 m
Base thickness0.3 m
Concrete weight24 kN/m³
Pressure methodRankine
Friction angle φ′28 °
Backfill slope β0 °
Backfill weight γ18.5 kN/m³
Uniform surcharge q24 kPa
Base friction μ0.4
Backfill waterDrained

Method & assumptions

  1. Model the concrete and soil over the heel as a single gravity block. Apply active pressure on a vertical plane at the heel, where retained height is H + heel × tan β.
  2. For dry backfill, Pa = Ka(½γH² + qH) using the effective height at the heel. Soil thrust acts at one-third height and surcharge thrust at half height. Rankine inclines down by β. Coulomb uses the equivalent angle δ on the assumed heel plane.
  3. The reference Kp assumes level ground and a smooth passive plane. Water reduces effective soil pressure below its level and adds a separate horizontal hydrostatic triangle. The wet screen assumes no water in front and applies full heel water pressure uniformly under the base.
  4. Sliding F.S. = μV / Ph. Overturning F.S. is the ratio of resisting to driving moment about the toe. Positive eccentricity is toward the toe. Full contact uses V/B(1 ± 6e/B). Beyond the middle third, the base uses a compression-only triangle where a resultant remains within the base.
  5. Illustrative limits are 1.50 sliding and 2.00 overturning. Count base friction on net normal load, with zero passive resistance credit. Check site-specific bearing, global stability and the actual groundwater and uplift distribution.

More worked examples