Worked example
Lab data above the zero-air-voids ceiling
A reported Proctor point pairs unusually high dry weight with high water content.
Results
Edit inputs ↓- Dry weight
- 20 kN/m³
- Void ratio
- 0.309
- Saturation
- 181.3 %
- Porosity
- 23.6 %
- Solids
- Water
- Lab point
Measured dry weight exceeds the zero-air-voids ceiling. Review the laboratory readings.
Calculation details
| Bulk unit weight γ | 24.2 kN/m³ |
|---|---|
| Saturated unit weight γsat | 22.32 kN/m³ |
| Buoyant unit weight γ′ | 12.51 kN/m³ |
| Air fraction of total volume | -19.2 % |
| Zero-air-voids dry weight | 16.78 kN/m³ |
| Ceiling minus measured dry weight | -3.22 kN/m³ |
| Relative density Dr | — |
GeotechSoilLab · Screening sheet · Metric SI
Lab data above the zero-air-voids ceiling
| Water content w | 21 % |
|---|---|
| Solids specific gravity Gs | 2.67 |
| Measured weight basis | Dry weight |
| Measured unit weight | 20 kN/m³ |
| Relative density Dr | Skip |
| Dry weight | 20 kN/m³ |
|---|---|
| Void ratio | 0.309 |
| Saturation | 181.3 % |
| Porosity | 23.6 % |
| Bulk unit weight γ | 24.2 kN/m³ |
| Saturated unit weight γsat | 22.32 kN/m³ |
| Buoyant unit weight γ′ | 12.51 kN/m³ |
| Air fraction of total volume | -19.2 % |
| Zero-air-voids dry weight | 16.78 kN/m³ |
| Ceiling minus measured dry weight | -3.22 kN/m³ |
| Relative density Dr | — |
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Worked result
The measured point lies above the theoretical ceiling. Recheck mass, volume and water-content readings.
- Use γd = 20 kN/m³ and Gs = 2.67 to find e = 0.309 and porosity = 23.6%.
- At w = 21%, wGs/e gives a saturation of 181.3%.
- The zero-air-voids ceiling at this water content is 16.777 kN/m³. Ceiling minus measured dry weight is -3.223 kN/m³.
Dry weight20 kN/m³Void ratio0.309Saturation181.3 %Porosity23.6 %
Original case inputs
| Water content w | 21 % |
|---|---|
| Solids specific gravity Gs | 2.67 |
| Measured weight basis | Dry weight |
| Measured unit weight | 20 kN/m³ |
| Relative density Dr | Skip |
Method & assumptions
- A bulk unit weight converts to γd = γ/(1 + w). The model takes w as a mass ratio and uses γw = 9.80665 kN/m³.
- e = Gsγw/γd − 1, n = e/(1 + e) and Sr = wGs/e. Saturated weight is γw(Gs + e)/(1 + e). Buoyant weight subtracts γw from that value.
- The zero-air-voids curve uses γd,zav = Gsγw/(1 + wGs). A specimen above the curve implies more water volume than void space. The plot preserves the measured point for diagnosis.
- For granular material, enter index-density void ratios to compute Dr = (emax − e)/(emax − emin). Relative density and percent Proctor compaction use different reference measurements.
More worked examples
- Dry unit weight from a bulk measurementA moist specimen’s total weight and volume give a bulk unit weight of 19.4 kN/m³.
- Phase volumes for oven-dry sandA granular specimen has been oven-dried and compacted into a known volume.
- Relative density of a loose sandA field sand specimen is compared with minimum and maximum index void ratios.
- Specimen on the zero-air-voids curveLab values are chosen to represent a fully saturated specimen with e = 0.54.
- Silty clay bulk and buoyant weightsA moist silty-clay sample is weighed at its natural water content.