Soil phase relationships

Resolve air, water and solids from lab measurements and compare dry weight to the Proctor ceiling.

Dry weight
17.5 kN/m³
Void ratio
0.502
Saturation
69.4 %
Porosity
33.4 %
Phase volumes & zero-air-voids curve Schematic
Phase volumes & zero-air-voids curve, schematic Air 10.2%Water 23.2%Solids 66.6%Volume fractionsZero-air-voids curven 33.4%Water content (%)Dry weight / ceiling89.8%
  • Solids
  • Water
  • Lab point

Measured dry weight is within the zero-air-voids ceiling at this water content.

Calculation details
Bulk unit weight γ19.78 kN/m³
Saturated unit weight γsat20.78 kN/m³
Buoyant unit weight γ′10.97 kN/m³
Air fraction of total volume10.2 %
Zero-air-voids dry weight19.49 kN/m³
Ceiling minus measured dry weight1.99 kN/m³
Relative density Dr—

Inputs

Laboratory measurements
Granular density context

Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.

Method & assumptions

  1. A bulk unit weight converts to γd = γ/(1 + w). The model takes w as a mass ratio and uses γw = 9.80665 kN/m³.
  2. e = Gsγw/γd − 1, n = e/(1 + e) and Sr = wGs/e. Saturated weight is γw(Gs + e)/(1 + e). Buoyant weight subtracts γw from that value.
  3. The zero-air-voids curve uses γd,zav = Gsγw/(1 + wGs). A specimen above the curve implies more water volume than void space. The plot preserves the measured point for diagnosis.
  4. For granular material, enter index-density void ratios to compute Dr = (emax − e)/(emax − emin). Relative density and percent Proctor compaction use different reference measurements.

Worked examples