Worked example

Specimen on the zero-air-voids curve

Lab values are chosen to represent a fully saturated specimen with e = 0.54.

Dry weight
17.19 kN/m³
Void ratio
0.54
Saturation
100 %
Porosity
35.1 %
Phase volumes & zero-air-voids curve Schematic
Phase volumes & zero-air-voids curve, schematic Air 1.34e-14%Water 35.1%Solids 64.9%Volume fractionsZero-air-voids curven 35.1%Water content (%)Dry weight / ceiling100%
  • Solids
  • Water
  • Lab point

Measured dry weight is within the zero-air-voids ceiling at this water content.

Calculation details
Bulk unit weight γ20.63 kN/m³
Saturated unit weight γsat20.63 kN/m³
Buoyant unit weight γ′10.83 kN/m³
Air fraction of total volume1.44e-14 %
Zero-air-voids dry weight17.19 kN/m³
Ceiling minus measured dry weight0 kN/m³
Relative density Dr—

Inputs

Laboratory measurements
Granular density context

Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.

Worked result

The water volume equals the entire void volume. Saturation is 100% and the dry-weight ceiling reserve is zero.

  1. Use γd = 17.193 kN/m³ and Gs = 2.7 to find e = 0.54 and porosity = 35.1%.
  2. At w = 20%, wGs/e gives a saturation of 100%.
  3. The zero-air-voids ceiling at this water content is 17.193 kN/m³. Ceiling minus measured dry weight is 0 kN/m³.
Dry weight17.19 kN/m³Void ratio0.54Saturation100 %Porosity35.1 %
Original case inputs
Water content w20 %
Solids specific gravity Gs2.7
Measured weight basisDry weight
Measured unit weight17.19348 kN/m³
Relative density DrSkip

Method & assumptions

  1. A bulk unit weight converts to γd = γ/(1 + w). The model takes w as a mass ratio and uses γw = 9.80665 kN/m³.
  2. e = Gsγw/γd − 1, n = e/(1 + e) and Sr = wGs/e. Saturated weight is γw(Gs + e)/(1 + e). Buoyant weight subtracts γw from that value.
  3. The zero-air-voids curve uses γd,zav = Gsγw/(1 + wGs). A specimen above the curve implies more water volume than void space. The plot preserves the measured point for diagnosis.
  4. For granular material, enter index-density void ratios to compute Dr = (emax − e)/(emax − emin). Relative density and percent Proctor compaction use different reference measurements.

More worked examples