Worked example
Dry unit weight from a bulk measurement
A moist specimen’s total weight and volume give a bulk unit weight of 19.4 kN/m³.
Results
Edit inputs ↓- Dry weight
- 16.99 kN/m³
- Void ratio
- 0.541
- Saturation
- 70 %
- Porosity
- 35.1 %
- Solids
- Water
- Lab point
Measured dry weight is within the zero-air-voids ceiling at this water content.
Calculation details
| Bulk unit weight γ | 19.4 kN/m³ |
|---|---|
| Saturated unit weight γsat | 20.43 kN/m³ |
| Buoyant unit weight γ′ | 10.63 kN/m³ |
| Air fraction of total volume | 10.5 % |
| Zero-air-voids dry weight | 18.99 kN/m³ |
| Ceiling minus measured dry weight | 2 kN/m³ |
| Relative density Dr | — |
GeotechSoilLab · Screening sheet · Metric SI
Dry unit weight from a bulk measurement
| Water content w | 14.2 % |
|---|---|
| Solids specific gravity Gs | 2.67 |
| Measured weight basis | Bulk weight |
| Measured unit weight | 19.4 kN/m³ |
| Relative density Dr | Skip |
| Dry weight | 16.99 kN/m³ |
|---|---|
| Void ratio | 0.541 |
| Saturation | 70 % |
| Porosity | 35.1 % |
| Bulk unit weight γ | 19.4 kN/m³ |
| Saturated unit weight γsat | 20.43 kN/m³ |
| Buoyant unit weight γ′ | 10.63 kN/m³ |
| Air fraction of total volume | 10.5 % |
| Zero-air-voids dry weight | 18.99 kN/m³ |
| Ceiling minus measured dry weight | 2 kN/m³ |
| Relative density Dr | — |
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Worked result
Divide by 1 + w first. Use the resulting dry weight to calculate void ratio and saturation.
- Use γd = 16.988 kN/m³ and Gs = 2.67 to find e = 0.541 and porosity = 35.1%.
- At w = 14.2%, wGs/e gives a saturation of 70%.
- The zero-air-voids ceiling at this water content is 18.986 kN/m³. Ceiling minus measured dry weight is 1.998 kN/m³.
Dry weight16.99 kN/m³Void ratio0.541Saturation70 %Porosity35.1 %
Original case inputs
| Water content w | 14.2 % |
|---|---|
| Solids specific gravity Gs | 2.67 |
| Measured weight basis | Bulk weight |
| Measured unit weight | 19.4 kN/m³ |
| Relative density Dr | Skip |
Method & assumptions
- A bulk unit weight converts to γd = γ/(1 + w). The model takes w as a mass ratio and uses γw = 9.80665 kN/m³.
- e = Gsγw/γd − 1, n = e/(1 + e) and Sr = wGs/e. Saturated weight is γw(Gs + e)/(1 + e). Buoyant weight subtracts γw from that value.
- The zero-air-voids curve uses γd,zav = Gsγw/(1 + wGs). A specimen above the curve implies more water volume than void space. The plot preserves the measured point for diagnosis.
- For granular material, enter index-density void ratios to compute Dr = (emax − e)/(emax − emin). Relative density and percent Proctor compaction use different reference measurements.
More worked examples
- Phase volumes for oven-dry sandA granular specimen has been oven-dried and compacted into a known volume.
- Relative density of a loose sandA field sand specimen is compared with minimum and maximum index void ratios.
- Specimen on the zero-air-voids curveLab values are chosen to represent a fully saturated specimen with e = 0.54.
- Lab data above the zero-air-voids ceilingA reported Proctor point pairs unusually high dry weight with high water content.
- Silty clay bulk and buoyant weightsA moist silty-clay sample is weighed at its natural water content.