Airport hotel low-frequency check

A hotel facade is compared at a low target band where the cavity spring is important.

Mass–air–mass · STC/OITC screening

Inputs

Double glazing
mm
mm
mm
Noise target
Hz
dB

Screening result

Predicted loss in the target band is below the selected target.

Fail
Target-band TL
21.1dB
Cavity dip
129Hz
STC estimate
45
OITC estimate
34
Double-pane section and transmission-loss spectrumGlazing acoustics. Target-band TL 21.1 dB. Cavity dip 129 Hz. STC estimate 45. OITC estimate 34.Two-pane acoustic section8 mm and 12 mm panesGap 18 mmTransmission lossModeled dB · log frequency90050 Hz10 kHzCavity dipCoincidenceTargetPredicted target-band reserve−10 dBTarget+10 dB

Calculation details

Combined glass surface mass
50 kg/m²
Mass-law loss at target band
28.9 dB
Pane 1 coincidence frequency
1495 Hz
Pane 2 coincidence frequency
996 Hz
Target-band reserve
-8.9 dB
Thick-to-thin pane ratio
1.5
Pane asymmetry
Current thickness ratio separates the two dip centers.

Formula trace in SI

  1. Mass law

    TLmass = 20 log₁₀[(m₁ + m₂) f] − 47

    50 kg/m² at 125 Hz → 28.9 dB.

  2. Resonant frequencies

    fmam = √[(K/d)(1/m₁ + 1/m₂)]/(2π); fc = c²√(m/D)/(2π)

    Cavity 129 Hz, glass 1495 Hz and 996 Hz.

  3. Target band

    TLscreen = TLmass + cavity gain − resonance and coincidence penalties

    Predicted 21.1 dB, reserve -8.9 dB.

  4. Screening classes

    Speech contour fit and A-weighted outdoor spectrum energy loss

    STC estimate 45, OITC estimate 34 from the synthetic spectrum.