GlassFacadeLab · Mass–air–mass · STC/OITC screening
Matched panes at coincidence
Worked example · SI
Warn · Predicted loss is within 3 dB of the target.
Inputs
- Pane 1 thickness
- 8 mm
- Pane 2 thickness
- 8 mm
- Air or gas cavity
- 16 mm
- Cavity gas
- Air
- Laminated damping
- Unlaminated baseline
- Target band center
- 1520 Hz
- Target transmission loss
- 48 dB
Results
- Target-band TL
- 48.8 dB
- Cavity dip
- 150 Hz
- STC estimate
- 43
- OITC estimate
- 33
- Combined glass surface mass
- 40 kg/m²
- Mass-law loss at target band
- 48.7 dB
- Pane 1 coincidence frequency
- 1495 Hz
- Pane 2 coincidence frequency
- 1495 Hz
- Target-band reserve
- 0.8 dB
- Thick-to-thin pane ratio
- 1
Formula trace in SI
Mass law
TLmass = 20 log₁₀[(m₁ + m₂) f] − 47
40 kg/m² at 1520 Hz → 48.7 dB.
Resonant frequencies
fmam = √[(K/d)(1/m₁ + 1/m₂)]/(2π); fc = c²√(m/D)/(2π)
Cavity 150 Hz, glass 1495 Hz and 1495 Hz.
Target band
TLscreen = TLmass + cavity gain − resonance and coincidence penalties
Predicted 48.8 dB, reserve 0.8 dB.
Screening classes
Speech contour fit and A-weighted outdoor spectrum energy loss
STC estimate 43, OITC estimate 33 from the synthetic spectrum.