Rail-side laminated facade

A heavy secondary pane and damped glazing are screened at a rail-noise band.

Mass–air–mass · STC/OITC screening

Inputs

Double glazing
mm
mm
mm
Noise target
Hz
dB

Screening result

Current thickness ratio separates the two dip centers.

Pass
Target-band TL
59.1dB
Cavity dip
100Hz
STC estimate
52
OITC estimate
36
Double-pane section and transmission-loss spectrumGlazing acoustics. Target-band TL 59.1 dB. Cavity dip 100 Hz. STC estimate 52. OITC estimate 36.Two-pane acoustic section10 mm and 16 mm panesGap 28 mmTransmission lossModeled dB · log frequency90050 Hz10 kHzCavity dipCoincidenceTargetPredicted target-band reserve−10 dBTarget+10 dB

Calculation details

Combined glass surface mass
65 kg/m²
Mass-law loss at target band
49.3 dB
Pane 1 coincidence frequency
1196 Hz
Pane 2 coincidence frequency
747 Hz
Target-band reserve
15.1 dB
Thick-to-thin pane ratio
1.6
Pane asymmetry
Current thickness ratio separates the two dip centers.

Formula trace in SI

  1. Mass law

    TLmass = 20 log₁₀[(m₁ + m₂) f] − 47

    65 kg/m² at 1000 Hz → 49.3 dB.

  2. Resonant frequencies

    fmam = √[(K/d)(1/m₁ + 1/m₂)]/(2π); fc = c²√(m/D)/(2π)

    Cavity 100 Hz, glass 1196 Hz and 747 Hz.

  3. Target band

    TLscreen = TLmass + cavity gain − resonance and coincidence penalties

    Predicted 59.1 dB, reserve 15.1 dB.

  4. Screening classes

    Speech contour fit and A-weighted outdoor spectrum energy loss

    STC estimate 52, OITC estimate 36 from the synthetic spectrum.