GlassFacadeLab · Mass–air–mass · STC/OITC screening
Secondary glazing with deep cavity
Worked example · SI
Warn · Predicted loss is within 3 dB of the target.
Inputs
- Pane 1 thickness
- 4 mm
- Pane 2 thickness
- 8 mm
- Air or gas cavity
- 95 mm
- Cavity gas
- Air
- Laminated damping
- Unlaminated baseline
- Target band center
- 160 Hz
- Target transmission loss
- 29 dB
Results
- Target-band TL
- 30.4 dB
- Cavity dip
- 75 Hz
- STC estimate
- 48
- OITC estimate
- 31
- Combined glass surface mass
- 30 kg/m²
- Mass-law loss at target band
- 26.6 dB
- Pane 1 coincidence frequency
- 2989 Hz
- Pane 2 coincidence frequency
- 1495 Hz
- Target-band reserve
- 1.4 dB
- Thick-to-thin pane ratio
- 2
Formula trace in SI
Mass law
TLmass = 20 log₁₀[(m₁ + m₂) f] − 47
30 kg/m² at 160 Hz → 26.6 dB.
Resonant frequencies
fmam = √[(K/d)(1/m₁ + 1/m₂)]/(2π); fc = c²√(m/D)/(2π)
Cavity 75 Hz, glass 2989 Hz and 1495 Hz.
Target band
TLscreen = TLmass + cavity gain − resonance and coincidence penalties
Predicted 30.4 dB, reserve 1.4 dB.
Screening classes
Speech contour fit and A-weighted outdoor spectrum energy loss
STC estimate 48, OITC estimate 31 from the synthetic spectrum.