Secondary glazing with deep cavity

A separate inner glazing line creates an unusually deep cavity.

Mass–air–mass · STC/OITC screening

Inputs

Double glazing
mm
mm
mm
Noise target
Hz
dB

Screening result

Predicted loss is within 3 dB of the target.

Warn
Target-band TL
30.4dB
Cavity dip
75Hz
STC estimate
48
OITC estimate
31
Double-pane section and transmission-loss spectrumGlazing acoustics. Target-band TL 30.4 dB. Cavity dip 75 Hz. STC estimate 48. OITC estimate 31.Two-pane acoustic section4 mm and 8 mm panesGap 95 mmTransmission lossModeled dB · log frequency80050 Hz10 kHzCavity dipCoincidenceTargetPredicted target-band reserve−10 dBTarget+10 dB

Calculation details

Combined glass surface mass
30 kg/m²
Mass-law loss at target band
26.6 dB
Pane 1 coincidence frequency
2989 Hz
Pane 2 coincidence frequency
1495 Hz
Target-band reserve
1.4 dB
Thick-to-thin pane ratio
2
Pane asymmetry
Current thickness ratio separates the two dip centers.

Formula trace in SI

  1. Mass law

    TLmass = 20 log₁₀[(m₁ + m₂) f] − 47

    30 kg/m² at 160 Hz → 26.6 dB.

  2. Resonant frequencies

    fmam = √[(K/d)(1/m₁ + 1/m₂)]/(2π); fc = c²√(m/D)/(2π)

    Cavity 75 Hz, glass 2989 Hz and 1495 Hz.

  3. Target band

    TLscreen = TLmass + cavity gain − resonance and coincidence penalties

    Predicted 30.4 dB, reserve 1.4 dB.

  4. Screening classes

    Speech contour fit and A-weighted outdoor spectrum energy loss

    STC estimate 48, OITC estimate 31 from the synthetic spectrum.