GlassFacadeLab · Mass–air–mass · STC/OITC screening
Airport hotel low-frequency check
Worked example · SI
Fail · Predicted loss in the target band is below the selected target.
Inputs
- Pane 1 thickness
- 8 mm
- Pane 2 thickness
- 12 mm
- Air or gas cavity
- 18 mm
- Cavity gas
- Air
- Laminated damping
- Damped coincidence estimate
- Target band center
- 125 Hz
- Target transmission loss
- 30 dB
Results
- Target-band TL
- 21.1 dB
- Cavity dip
- 129 Hz
- STC estimate
- 45
- OITC estimate
- 34
- Combined glass surface mass
- 50 kg/m²
- Mass-law loss at target band
- 28.9 dB
- Pane 1 coincidence frequency
- 1495 Hz
- Pane 2 coincidence frequency
- 996 Hz
- Target-band reserve
- -8.9 dB
- Thick-to-thin pane ratio
- 1.5
Formula trace in SI
Mass law
TLmass = 20 log₁₀[(m₁ + m₂) f] − 47
50 kg/m² at 125 Hz → 28.9 dB.
Resonant frequencies
fmam = √[(K/d)(1/m₁ + 1/m₂)]/(2π); fc = c²√(m/D)/(2π)
Cavity 129 Hz, glass 1495 Hz and 996 Hz.
Target band
TLscreen = TLmass + cavity gain − resonance and coincidence penalties
Predicted 21.1 dB, reserve -8.9 dB.
Screening classes
Speech contour fit and A-weighted outdoor spectrum energy loss
STC estimate 45, OITC estimate 34 from the synthetic spectrum.