Glazed roof wind uplift

Wind suction exceeds the inward normal component of glass weight.

GANA setting-block screen

Inputs

Slope, glass and loading
°
m
m
mm
kg/m³
kPa
kPa

Positive presses toward the frame.

Setting blocks
mm
Shore A
%

25% places blocks at the quarter points.

MPa

Use the block manufacturer’s allowable pressure.

Screening result

Net wind uplift requires a separate retention check.

Warn
Normal load
-1kPa
In-plane force
310N
Min. block
101.6mm
Block bearing
0.1MPa
Sloped-glass free-body diagram and setting blocksSkylight snow and blocks. Normal load -1 kPa. In-plane force 310 N. Min. block 101.6 mm. Block bearing 0.1 MPa.Sloped glass load components27 ° from horizontalWeightNormalThrustLower edge block placementBlock length 115 mm25 % from each cornerGoverning block demand0%100% limit200%+

Calculation details

Total glass weight
681.823 N
Total glass mass
69.527 kg
Dead load per glass area
0.331 kPa
Snow resultant per glass area
0 kPa
Glass-only downslope thrust
309.541 N
Gravity and snow thrust per block
154.771 N
Minimum block width (glass + 1/8 in)
16.695 mm
Clearance from corner to block end
245 mm

Formula trace in SI

  1. Weight and snow basis

    W = ρ t A g; p_snow = p_roof cos θ for plan-area pressure

    W = 681.823 N, converted p_snow = 0 kPa.

  2. Slope components

    qn = (pd + ps) cos θ + pw; F∥ = (pd + ps) A sin θ

    Angle 27 °, qn = -1.005 kPa, F∥ = 309.541 N.

  3. Block length

    ℓmin = max(4 in, 0.1 in × area in ft²)

    Per-block minimum 101.6 mm, provided 115 mm.

  4. Edge bearing

    pblock = F∥ / (2 ℓblock tglass)

    0.1 MPa versus 0.85 MPa allowance.