Skylight loads and setting-block calculator

Resolve gravity and wind on a sloped lite and check two equal lower-edge setting blocks.

GANA setting-block screen

Inputs

Slope, glass and loading
°
m
m
mm
kg/m³
kPa
kPa

Positive presses toward the frame.

Setting blocks
mm
Shore A
%

25% places blocks at the quarter points.

MPa

Use the block manufacturer’s allowable pressure.

Screening result

Both modeled setting blocks satisfy the selected length and bearing checks.

Pass
Normal load
1.45kPa
In-plane force
1350N
Min. block
101.6mm
Block bearing
0.416MPa
Sloped-glass free-body diagram and setting blocksSkylight snow and blocks. Normal load 1.45 kPa. In-plane force 1350 N. Min. block 101.6 mm. Block bearing 0.416 MPa.Sloped glass load components30 ° from horizontalWeightNormalThrustLower edge block placementBlock length 120 mm25 % from each cornerGoverning block demand0%100% limit200%+

Calculation details

Total glass weight
775.628 N
Total glass mass
79.092 kg
Dead load per glass area
0.331 kPa
Snow resultant per glass area
0.823 kPa
Glass-only downslope thrust
387.814 N
Gravity and snow thrust per block
675.201 N
Minimum block width (glass + 1/8 in)
16.695 mm
Clearance from corner to block end
265 mm

Formula trace in SI

  1. Weight and snow basis

    W = ρ t A g; p_snow = p_roof cos θ for plan-area pressure

    W = 775.628 N, converted p_snow = 0.823 kPa.

  2. Slope components

    qn = (pd + ps) cos θ + pw; F∥ = (pd + ps) A sin θ

    Angle 30 °, qn = 1.45 kPa, F∥ = 1350.401 N.

  3. Block length

    ℓmin = max(4 in, 0.1 in × area in ft²)

    Per-block minimum 101.6 mm, provided 120 mm.

  4. Edge bearing

    pblock = F∥ / (2 ℓblock tglass)

    0.416 MPa versus 0.85 MPa allowance.