GlassFacadeLab · GANA setting-block screen
Pitched atrium with ground snow input
Worked example · SI
Fail · Block length, fit or bearing is outside the entered limit.
Inputs
- Slope from horizontal
- 34 °
- Lower edge width
- 1.76 m
- Length up the slope
- 2.36 m
- Laminated thickness
- 17.52 mm
- Glass density
- 2500 kg/m³
- Snow pressure
- 2.5 kPa
- Snow input basis
- Ground · horizontal plan
- Ground-to-roof multiplier
- 0.74
- Normal wind pressure
- 0.5 kPa
- Provided block length
- 140 mm
- Setting-block hardness
- 85 Shore A
- Block center from corner
- 25 %
- Bearing allowance
- 0.85 MPa
Results
- Normal load
- 2.13 kPa
- In-plane force
- 4560 N
- Min. block
- 113.6 mm
- Block bearing
- 0.93 MPa
- Total glass weight
- 1784.101 N
- Total glass mass
- 181.928 kg
- Dead load per glass area
- 0.43 kPa
- Snow resultant per glass area
- 1.534 kPa
- Glass-only downslope thrust
- 997.657 N
- Gravity and snow thrust per block
- 2279.986 N
- Minimum block width (glass + 1/8 in)
- 20.695 mm
- Clearance from corner to block end
- 370 mm
Formula trace in SI
Weight and snow basis
W = ρ t A g; p_snow = p_roof cos θ for plan-area pressure
W = 1784.101 N, converted p_snow = 1.534 kPa.
Slope components
qn = (pd + ps) cos θ + pw; F∥ = (pd + ps) A sin θ
Angle 34 °, qn = 2.128 kPa, F∥ = 4559.971 N.
Block length
ℓmin = max(4 in, 0.1 in × area in ft²)
Per-block minimum 113.561 mm, provided 140 mm.
Edge bearing
pblock = F∥ / (2 ℓblock tglass)
0.93 MPa versus 0.85 MPa allowance.