Wide skylight with long setting blocks

A broad continuous lite needs blocks longer than the 4-inch minimum.

GANA setting-block screen

Inputs

Slope, glass and loading
°
m
m
mm
kg/m³
kPa
kPa

Positive presses toward the frame.

Setting blocks
mm
Shore A
%

25% places blocks at the quarter points.

MPa

Use the block manufacturer’s allowable pressure.

Screening result

Block length, fit or bearing is outside the entered limit.

Fail
Normal load
2.76kPa
In-plane force
5115N
Min. block
181.1mm
Block bearing
0.792MPa
Sloped-glass free-body diagram and setting blocksSkylight snow and blocks. Normal load 2.76 kPa. In-plane force 5115 N. Min. block 181.1 mm. Block bearing 0.792 MPa.Sloped glass load components19 ° from horizontalWeightNormalThrustLower edge block placementBlock length 150 mm25 % from each cornerGoverning block demand0%100% limit200%+

Calculation details

Total glass weight
3495.335 N
Total glass mass
356.425 kg
Dead load per glass area
0.528 kPa
Snow resultant per glass area
1.844 kPa
Glass-only downslope thrust
1137.97 N
Gravity and snow thrust per block
2557.379 N
Minimum block width (glass + 1/8 in)
24.695 mm
Clearance from corner to block end
550 mm

Formula trace in SI

  1. Weight and snow basis

    W = ρ t A g; p_snow = p_roof cos θ for plan-area pressure

    W = 3495.335 N, converted p_snow = 1.844 kPa.

  2. Slope components

    qn = (pd + ps) cos θ + pw; F∥ = (pd + ps) A sin θ

    Angle 19 °, qn = 2.762 kPa, F∥ = 5114.758 N.

  3. Block length

    ℓmin = max(4 in, 0.1 in × area in ft²)

    Per-block minimum 181.13 mm, provided 150 mm.

  4. Edge bearing

    pblock = F∥ / (2 ℓblock tglass)

    0.792 MPa versus 0.85 MPa allowance.