GlassFacadeLab · GANA setting-block screen
Glazed roof wind uplift
Worked example · SI
Warn · Net wind uplift requires a separate retention check.
Inputs
- Slope from horizontal
- 27 °
- Lower edge width
- 1.21 m
- Length up the slope
- 1.7 m
- Laminated thickness
- 13.52 mm
- Glass density
- 2500 kg/m³
- Snow pressure
- 0 kPa
- Snow input basis
- Roof · horizontal plan
- Normal wind pressure
- -1.3 kPa
- Provided block length
- 115 mm
- Setting-block hardness
- 85 Shore A
- Block center from corner
- 25 %
- Bearing allowance
- 0.85 MPa
Results
- Normal load
- -1 kPa
- In-plane force
- 310 N
- Min. block
- 101.6 mm
- Block bearing
- 0.1 MPa
- Total glass weight
- 681.823 N
- Total glass mass
- 69.527 kg
- Dead load per glass area
- 0.331 kPa
- Snow resultant per glass area
- 0 kPa
- Glass-only downslope thrust
- 309.541 N
- Gravity and snow thrust per block
- 154.771 N
- Minimum block width (glass + 1/8 in)
- 16.695 mm
- Clearance from corner to block end
- 245 mm
Formula trace in SI
Weight and snow basis
W = ρ t A g; p_snow = p_roof cos θ for plan-area pressure
W = 681.823 N, converted p_snow = 0 kPa.
Slope components
qn = (pd + ps) cos θ + pw; F∥ = (pd + ps) A sin θ
Angle 27 °, qn = -1.005 kPa, F∥ = 309.541 N.
Block length
ℓmin = max(4 in, 0.1 in × area in ft²)
Per-block minimum 101.6 mm, provided 115 mm.
Edge bearing
pblock = F∥ / (2 ℓblock tglass)
0.1 MPa versus 0.85 MPa allowance.