High bite with a narrow glue line

A proposed sealant joint has enough bite for suction and a shallow glue line.

ASTM C1401 · 1:1 to 3:1

Inputs

Lite and wind suction
m
m
kPa
kPa

138 kPa is approximately 20 psi.

Movement and proposed joint
K
µm/(m·K)
%

Use the approved structural shear strain.

mm
mm

Screening result

Proposed bite must be between one and three times the glue-line thickness.

Fail
Required bite
16.83mm
Min. glue line
6mm
Bite : glue
3.429 : 1
Movement
0.59mm
Structural silicone section and joint geometryStructural silicone joint. Required bite 16.83 mm. Min. glue line 6 mm. Bite : glue 3.429 : 1. Movement 0.59 mm.Structural glazing sectionLite width 1.72 m · 2.7 kPa suctionGlassSiliconeMullionProposed bond geometryThermal travel 0.59 mmBite 24 mmGlue line 7 mmBite-to-glue ratio (1:1–3:1)0:12:14:1+

Calculation details

Wind-only structural bite
16.826 mm
Movement-only glue line
4.704 mm
Compatible bite before rounding up
16.826 mm
Compatible glue line before rounding up
6 mm
Governing dimensional utilization
85.7 %

Formula trace in SI

  1. Wind suction bite

    Bwind = aₛ q / (2 σallow)

    1.72 m × 2.7 kPa / (2 × 138 kPa) → 16.826 mm.

  2. Differential movement

    Δ = |αAl − αglass| × Llong/2 × ΔT

    Glass CTE 9 µm/(m·K), relative travel 0.588 mm.

  3. Glue line and limits

    Gmove = Δ/γallow; B,G ≥ 6 mm; G ≤ B ≤ 3G

    At 12.5 % shear strain, Gmove = 4.704 mm. Minimum compatible B × G = 16.826 × 6 mm.