GlassFacadeLab · ASTM C1401 · 1:1 to 3:1
Unitized tower wind suction
Worked example · SI
Pass · The proposed joint satisfies the wind, movement and ratio screens.
Inputs
- Lite width a
- 1.48 m
- Lite height b
- 3.22 m
- Wind suction magnitude
- 3.55 kPa
- Allowable sealant tension
- 138 kPa
- Temperature excursion
- 48 K
- Aluminum expansion coefficient
- 23 µm/(m·K)
- Allowable shear strain
- 12.5 %
- Proposed bite
- 23 mm
- Proposed glue line
- 10 mm
Results
- Required bite
- 19.04 mm
- Min. glue line
- 8.66 mm
- Bite : glue
- 2.3 : 1
- Movement
- 1.08 mm
- Wind-only structural bite
- 19.036 mm
- Movement-only glue line
- 8.655 mm
- Compatible bite before rounding up
- 19.036 mm
- Compatible glue line before rounding up
- 8.655 mm
- Governing dimensional utilization
- 86.6 %
Formula trace in SI
Wind suction bite
Bwind = aₛ q / (2 σallow)
1.48 m × 3.55 kPa / (2 × 138 kPa) → 19.036 mm.
Differential movement
Δ = |αAl − αglass| × Llong/2 × ΔT
Glass CTE 9 µm/(m·K), relative travel 1.082 mm.
Glue line and limits
Gmove = Δ/γallow; B,G ≥ 6 mm; G ≤ B ≤ 3G
At 12.5 % shear strain, Gmove = 8.655 mm. Minimum compatible B × G = 19.036 × 8.655 mm.