Unitized tower wind suction

A four-sided unitized corner lite sees high suction with glass weight carried on blocks.

ASTM C1401 · 1:1 to 3:1

Inputs

Lite and wind suction
m
m
kPa
kPa

138 kPa is approximately 20 psi.

Movement and proposed joint
K
µm/(m·K)
%

Use the approved structural shear strain.

mm
mm

Screening result

The proposed joint satisfies the wind, movement and ratio screens.

Pass
Required bite
19.04mm
Min. glue line
8.66mm
Bite : glue
2.3 : 1
Movement
1.08mm
Structural silicone section and joint geometryStructural silicone joint. Required bite 19.04 mm. Min. glue line 8.66 mm. Bite : glue 2.3 : 1. Movement 1.08 mm.Structural glazing sectionLite width 1.48 m · 3.55 kPa suctionGlassSiliconeMullionProposed bond geometryThermal travel 1.08 mmBite 23 mmGlue line 10 mmBite-to-glue ratio (1:1–3:1)0:12:14:1+

Calculation details

Wind-only structural bite
19.036 mm
Movement-only glue line
8.655 mm
Compatible bite before rounding up
19.036 mm
Compatible glue line before rounding up
8.655 mm
Governing dimensional utilization
86.6 %

Formula trace in SI

  1. Wind suction bite

    Bwind = aₛ q / (2 σallow)

    1.48 m × 3.55 kPa / (2 × 138 kPa) → 19.036 mm.

  2. Differential movement

    Δ = |αAl − αglass| × Llong/2 × ΔT

    Glass CTE 9 µm/(m·K), relative travel 1.082 mm.

  3. Glue line and limits

    Gmove = Δ/γallow; B,G ≥ 6 mm; G ≤ B ≤ 3G

    At 12.5 % shear strain, Gmove = 8.655 mm. Minimum compatible B × G = 19.036 × 8.655 mm.