Structural silicone bite and glue-line calculator

Size a four-sided silicone joint for wind suction and differential glass-to-frame movement.

ASTM C1401 · 1:1 to 3:1

Inputs

Lite and wind suction
m
m
kPa
kPa

138 kPa is approximately 20 psi.

Movement and proposed joint
K
µm/(m·K)
%

Use the approved structural shear strain.

mm
mm

Screening result

The proposed bite or glue line is smaller than required.

Fail
Required bite
9.89mm
Min. glue line
8.32mm
Bite : glue
2 : 1
Movement
1.04mm
Structural silicone section and joint geometryStructural silicone joint. Required bite 9.89 mm. Min. glue line 8.32 mm. Bite : glue 2 : 1. Movement 1.04 mm.Structural glazing sectionLite width 1.3 m · 2.1 kPa suctionGlassSiliconeMullionProposed bond geometryThermal travel 1.04 mmBite 14 mmGlue line 7 mmBite-to-glue ratio (1:1–3:1)0:12:14:1+

Calculation details

Wind-only structural bite
9.891 mm
Movement-only glue line
8.316 mm
Compatible bite before rounding up
9.891 mm
Compatible glue line before rounding up
8.316 mm
Governing dimensional utilization
118.8 %

Formula trace in SI

  1. Wind suction bite

    Bwind = aₛ q / (2 σallow)

    1.3 m × 2.1 kPa / (2 × 138 kPa) → 9.891 mm.

  2. Differential movement

    Δ = |αAl − αglass| × Llong/2 × ΔT

    Glass CTE 9 µm/(m·K), relative travel 1.04 mm.

  3. Glue line and limits

    Gmove = Δ/γallow; B,G ≥ 6 mm; G ≤ B ≤ 3G

    At 12.5 % shear strain, Gmove = 8.316 mm. Minimum compatible B × G = 9.891 × 8.316 mm.