GlassFacadeLab · Wölfel–Bennison · EN 16612 context
Uncoupled laminate reference
Worked example · SI
Warn · Shear coupling is low for this temperature, duration and span.
Inputs
- Ply 1 thickness
- 8 mm
- Ply 2 thickness
- 8 mm
- Interlayer thickness
- 1.52 mm
- Simple span a
- 1.85 m
- Interlayer family
- Enter product G
- Temperature and duration
- 20 °C / 68 °F · 3 s
- Interlayer shear modulus G
- 0 MPa
Results
- Shear transfer
- 0 %
- Defl. eff. t
- 10.08 mm
- Ply 1 stress t
- 11.31 mm
- Ply 2 stress t
- 11.31 mm
- Applied interlayer shear modulus
- 0 MPa
- Uncoupled effective thickness
- 10.079 mm
- Fully coupled effective thickness
- 17.516 mm
- Stiffness over uncoupled plies
- 1
- Fraction of fully coupled stiffness
- 19.1 %
Formula trace in SI
Interlayer coupling
ω = G / (G + 9.6 E A* hv / L²)
G = 0 MPa, reduced area per width A* = 4 mm, ω = 0 %.
Equivalent bending thickness
heff,w³ = h₁³ + h₂³ + 12ωA*H²
Ply centroid distance H = 9.52 mm, heff,w = 10.079 mm.
Surface bending stress thickness
heff,σ,i = √[heff,w³/(hi + 2ωdi)]
Ply 1 11.314 mm, ply 2 11.314 mm.
Stiffness gain
Ieff / Ilayered = heff,w³ / (h₁³ + h₂³)
1× the uncoupled limit.