Matched panes at coincidence

Two equal panes put their coincidence dips in the same frequency region.

Mass–air–mass · STC/OITC screening

Inputs

Double glazing
mm
mm
mm
Noise target
Hz
dB

Screening result

Predicted loss is within 3 dB of the target.

Warn
Target-band TL
48.8dB
Cavity dip
150Hz
STC estimate
43
OITC estimate
33
Double-pane section and transmission-loss spectrumGlazing acoustics. Target-band TL 48.8 dB. Cavity dip 150 Hz. STC estimate 43. OITC estimate 33.Two-pane acoustic section8 mm and 8 mm panesGap 16 mmTransmission lossModeled dB · log frequency80050 Hz10 kHzCavity dipCoincidenceTargetPredicted target-band reserve−10 dBTarget+10 dB

Calculation details

Combined glass surface mass
40 kg/m²
Mass-law loss at target band
48.7 dB
Pane 1 coincidence frequency
1495 Hz
Pane 2 coincidence frequency
1495 Hz
Target-band reserve
0.8 dB
Thick-to-thin pane ratio
1
Pane asymmetry
Compare a thicker pane at least 1.5× the thinner pane and recheck the target band.

Formula trace in SI

  1. Mass law

    TLmass = 20 log₁₀[(m₁ + m₂) f] − 47

    40 kg/m² at 1520 Hz → 48.7 dB.

  2. Resonant frequencies

    fmam = √[(K/d)(1/m₁ + 1/m₂)]/(2π); fc = c²√(m/D)/(2π)

    Cavity 150 Hz, glass 1495 Hz and 1495 Hz.

  3. Target band

    TLscreen = TLmass + cavity gain − resonance and coincidence penalties

    Predicted 48.8 dB, reserve 0.8 dB.

  4. Screening classes

    Speech contour fit and A-weighted outdoor spectrum energy loss

    STC estimate 43, OITC estimate 33 from the synthetic spectrum.