GlassFacadeLab · Mass–air–mass · STC/OITC screening
Rail-side laminated facade
Worked example · SI
Pass · Current thickness ratio separates the two dip centers.
Inputs
- Pane 1 thickness
- 10 mm
- Pane 2 thickness
- 16 mm
- Air or gas cavity
- 28 mm
- Cavity gas
- Argon
- Laminated damping
- Damped coincidence estimate
- Target band center
- 1000 Hz
- Target transmission loss
- 44 dB
Results
- Target-band TL
- 59.1 dB
- Cavity dip
- 100 Hz
- STC estimate
- 52
- OITC estimate
- 36
- Combined glass surface mass
- 65 kg/m²
- Mass-law loss at target band
- 49.3 dB
- Pane 1 coincidence frequency
- 1196 Hz
- Pane 2 coincidence frequency
- 747 Hz
- Target-band reserve
- 15.1 dB
- Thick-to-thin pane ratio
- 1.6
Formula trace in SI
Mass law
TLmass = 20 log₁₀[(m₁ + m₂) f] − 47
65 kg/m² at 1000 Hz → 49.3 dB.
Resonant frequencies
fmam = √[(K/d)(1/m₁ + 1/m₂)]/(2π); fc = c²√(m/D)/(2π)
Cavity 100 Hz, glass 1196 Hz and 747 Hz.
Target band
TLscreen = TLmass + cavity gain − resonance and coincidence penalties
Predicted 59.1 dB, reserve 15.1 dB.
Screening classes
Speech contour fit and A-weighted outdoor spectrum energy loss
STC estimate 52, OITC estimate 36 from the synthetic spectrum.