GlassFacadeLab · Wölfel–Bennison · EN 16612 context
Warm PVB sustained load
Worked example · SI
Warn · Shear coupling is low for this temperature, duration and span.
Inputs
- Ply 1 thickness
- 8 mm
- Ply 2 thickness
- 10 mm
- Interlayer thickness
- 1.52 mm
- Simple span a
- 1.2 m
- Interlayer family
- PVB sensitivity preset
- Temperature and duration
- 50 °C / 122 °F · 1 h
Results
- Shear transfer
- 3.1 %
- Defl. eff. t
- 11.92 mm
- Ply 1 stress t
- 14.23 mm
- Ply 2 stress t
- 12.83 mm
- Applied interlayer shear modulus
- 0.1 MPa
- Uncoupled effective thickness
- 11.478 mm
- Fully coupled effective thickness
- 19.5 mm
- Stiffness over uncoupled plies
- 1.12
- Fraction of fully coupled stiffness
- 22.8 %
Formula trace in SI
Interlayer coupling
ω = G / (G + 9.6 E A* hv / L²)
G = 0.1 MPa, reduced area per width A* = 4.444 mm, ω = 3.07 %.
Equivalent bending thickness
heff,w³ = h₁³ + h₂³ + 12ωA*H²
Ply centroid distance H = 10.52 mm, heff,w = 11.92 mm.
Surface bending stress thickness
heff,σ,i = √[heff,w³/(hi + 2ωdi)]
Ply 1 14.233 mm, ply 2 12.83 mm.
Stiffness gain
Ieff / Ilayered = heff,w³ / (h₁³ + h₂³)
1.12× the uncoupled limit.