GlassFacadeLab · Wölfel–Bennison · EN 16612 context
Laminated glass effective-thickness calculator
Calculator scenario · SI
Pass · Interlayer shear measurably increases the modeled bending stiffness.
Inputs
- Ply 1 thickness
- 6 mm
- Ply 2 thickness
- 8 mm
- Interlayer thickness
- 1.52 mm
- Simple span a
- 1.5 m
- Interlayer family
- PVB sensitivity preset
- Temperature and duration
- 20 °C / 68 °F · 3 s
Results
- Shear transfer
- 81.8 %
- Defl. eff. t
- 14.69 mm
- Ply 1 stress t
- 15.07 mm
- Ply 2 stress t
- 15.06 mm
- Applied interlayer shear modulus
- 7 MPa
- Uncoupled effective thickness
- 8.996 mm
- Fully coupled effective thickness
- 15.487 mm
- Stiffness over uncoupled plies
- 4.356
- Fraction of fully coupled stiffness
- 85.4 %
Formula trace in SI
Interlayer coupling
ω = G / (G + 9.6 E A* hv / L²)
G = 7 MPa, reduced area per width A* = 3.429 mm, ω = 81.81 %.
Equivalent bending thickness
heff,w³ = h₁³ + h₂³ + 12ωA*H²
Ply centroid distance H = 8.52 mm, heff,w = 14.692 mm.
Surface bending stress thickness
heff,σ,i = √[heff,w³/(hi + 2ωdi)]
Ply 1 15.069 mm, ply 2 15.064 mm.
Stiffness gain
Ieff / Ilayered = heff,w³ / (h₁³ + h₂³)
4.356× the uncoupled limit.