Worked example · String Tension & Gauge

A 24.75-inch guitar with a 10–52 drop D set

A shorter-scale guitar gets a heavier bottom three strings for drop D. The test is whether the .052 low D regains useful pull without changing the plain strings.

Try this Put the lowest string back to E2 and compare its tension before deciding whether the same set suits both tunings.

Inputs

View results ↓
in12–45 in
in12–45 in
Hz400–480 Hz
lbfEnter zero to match the current average. 0–112.404 lbf

Strings · bass to treble

String 1
mil4–150 mil
String 2
mil4–150 mil
String 3
mil4–150 mil
String 4
mil4–150 mil
String 5
mil4–150 mil
String 6
mil4–150 mil
Total neck pull
110.45 lbf
Average per string
18.41 lbf
Balance target
16 lbf

String tension and neck pull

String tension and neck pullBars show tension by string. The dashed line marks the balance target and the neck view follows the selected scale endpoints. STRING FORCENECK PULLD216.5A224.8D323.6G315.7B314.6E415.4Target 16 lbf110.4 lbfSingle scale
Bars show tension by string. The dashed line marks the balance target and the neck view follows the selected scale endpoints.

String forces and suggested gauges
PitchHzConstructionScale (in)Gauge (mil)Tension (lbf)Suggested (mil)At suggestion (lbf)From target (lbf)
D273.42Nickel-wound24.755216.465216.460.46
A2110Nickel-wound24.754224.793416.580.58
D3146.83Nickel-wound24.753023.582414.86-1.14
G3196Plain steel24.751715.691715.69-0.31
B3246.94Plain steel24.751314.571416.90.9
E4329.63Plain steel24.751015.361015.36-0.64
Total neck pull 110.45 lbf

How the calculation works

From pitch to pull

Mersenne’s law gives T = μ(2Lf)². The math uses kilograms per meter for linear mass, meters for vibrating length and hertz for pitch. Each successive string takes one evenly spaced step between the two scale endpoints.

What “balanced” means here

The calculator searches the selected construction table for the stocked diameter whose force is closest to the target. Compare suggested force with target force before treating a set as balanced. Gauge, wrap and core can also change how a string feels.

Where the unit weights come from

Plain steel uses a solid-cylinder model and nominal steel density. Wound entries use selected D’Addario unit weights with log interpolation between listed gauges. Manufacturer construction, winding length and availability vary.

References

Questions at the bench

How much tension does the 52 mil string lose from E2 to D2?

At the same scale and gauge it keeps about 79% of its E2 tension, since the frequency ratio is squared.

Does the 10–52 set change the treble-side scale measurement?

The scale input stays 24.75 in. Enter different endpoint lengths only if the instrument geometry calls for it.