Worked example · String Tension & Gauge
A 24.75-inch guitar with a 10–52 drop D set
A shorter-scale guitar gets a heavier bottom three strings for drop D. The test is whether the .052 low D regains useful pull without changing the plain strings.
Try this Put the lowest string back to E2 and compare its tension before deciding whether the same set suits both tunings.
Inputs
Results
Back to inputs ↑- Total neck pull
- 110.45 lbf
- Average per string
- 18.41 lbf
- Balance target
- 16 lbf
String tension and neck pull
| Pitch | Hz | Construction | Scale (in) | Gauge (mil) | Tension (lbf) | Suggested (mil) | At suggestion (lbf) | From target (lbf) |
|---|---|---|---|---|---|---|---|---|
| D2 | 73.42 | Nickel-wound | 24.75 | 52 | 16.46 | 52 | 16.46 | 0.46 |
| A2 | 110 | Nickel-wound | 24.75 | 42 | 24.79 | 34 | 16.58 | 0.58 |
| D3 | 146.83 | Nickel-wound | 24.75 | 30 | 23.58 | 24 | 14.86 | -1.14 |
| G3 | 196 | Plain steel | 24.75 | 17 | 15.69 | 17 | 15.69 | -0.31 |
| B3 | 246.94 | Plain steel | 24.75 | 13 | 14.57 | 14 | 16.9 | 0.9 |
| E4 | 329.63 | Plain steel | 24.75 | 10 | 15.36 | 10 | 15.36 | -0.64 |
Input settings
- String family Guitar
- Treble scale 24.75 in
- Bass scale 24.75 in
- A4 reference 440 Hz
- Balance target per string 16 lbf
- string 1 · Pitch D2
- string 1 · Gauge 52 mil
- string 1 · Construction Nickel-wound
- string 2 · Pitch A2
- string 2 · Gauge 42 mil
- string 2 · Construction Nickel-wound
- string 3 · Pitch D3
- string 3 · Gauge 30 mil
- string 3 · Construction Nickel-wound
- string 4 · Pitch G3
- string 4 · Gauge 17 mil
- string 4 · Construction Plain steel
- string 5 · Pitch B3
- string 5 · Gauge 13 mil
- string 5 · Construction Plain steel
- string 6 · Pitch E4
- string 6 · Gauge 10 mil
- string 6 · Construction Plain steel
How the calculation works
From pitch to pull
Mersenne’s law gives T = μ(2Lf)². The math uses kilograms per meter for linear mass, meters for vibrating length and hertz for pitch. Each successive string takes one evenly spaced step between the two scale endpoints.
What “balanced” means here
The calculator searches the selected construction table for the stocked diameter whose force is closest to the target. Compare suggested force with target force before treating a set as balanced. Gauge, wrap and core can also change how a string feels.
Where the unit weights come from
Plain steel uses a solid-cylinder model and nominal steel density. Wound entries use selected D’Addario unit weights with log interpolation between listed gauges. Manufacturer construction, winding length and availability vary.
References
Questions at the bench
How much tension does the 52 mil string lose from E2 to D2?
At the same scale and gauge it keeps about 79% of its E2 tension, since the frequency ratio is squared.
Does the 10–52 set change the treble-side scale measurement?
The scale input stays 24.75 in. Enter different endpoint lengths only if the instrument geometry calls for it.