Worked example · String Tension & Gauge
Phosphor bronze 12–53 on a dreadnought
A 25.4 in acoustic uses a light phosphor-bronze set with a wound G. The 27 lbf reference is for comparing distribution within the set.
Try this Change only the wound G to a different bronze gauge and inspect the nearest stocked diameter and its force.
Inputs
Results
Back to inputs ↑- Total neck pull
- 162.37 lbf
- Average per string
- 27.06 lbf
- Balance target
- 27 lbf
String tension and neck pull
| Pitch | Hz | Construction | Scale (in) | Gauge (mil) | Tension (lbf) | Suggested (mil) | At suggestion (lbf) | From target (lbf) |
|---|---|---|---|---|---|---|---|---|
| E2 | 82.41 | Phosphor bronze | 25.4 | 53 | 25.86 | 53 | 25.86 | -1.14 |
| A2 | 110 | Phosphor bronze | 25.4 | 42 | 29.7 | 39 | 25.17 | -1.83 |
| D3 | 146.83 | Phosphor bronze | 25.4 | 32 | 30.29 | 30 | 26.89 | -0.11 |
| G3 | 196 | Phosphor bronze | 25.4 | 24 | 30 | 22 | 25.36 | -1.64 |
| B3 | 246.94 | Plain steel | 25.4 | 16 | 23.24 | 17 | 26.24 | -0.76 |
| E4 | 329.63 | Plain steel | 25.4 | 12 | 23.29 | 13 | 27.34 | 0.34 |
Input settings
- String family Guitar
- Treble scale 25.4 in
- Bass scale 25.4 in
- A4 reference 440 Hz
- Balance target per string 27 lbf
- string 1 · Pitch E2
- string 1 · Gauge 53 mil
- string 1 · Construction Phosphor bronze
- string 2 · Pitch A2
- string 2 · Gauge 42 mil
- string 2 · Construction Phosphor bronze
- string 3 · Pitch D3
- string 3 · Gauge 32 mil
- string 3 · Construction Phosphor bronze
- string 4 · Pitch G3
- string 4 · Gauge 24 mil
- string 4 · Construction Phosphor bronze
- string 5 · Pitch B3
- string 5 · Gauge 16 mil
- string 5 · Construction Plain steel
- string 6 · Pitch E4
- string 6 · Gauge 12 mil
- string 6 · Construction Plain steel
How the calculation works
From pitch to pull
Mersenne’s law gives T = μ(2Lf)². The math uses kilograms per meter for linear mass, meters for vibrating length and hertz for pitch. Each successive string takes one evenly spaced step between the two scale endpoints.
What “balanced” means here
The calculator searches the selected construction table for the stocked diameter whose force is closest to the target. Compare suggested force with target force before treating a set as balanced. Gauge, wrap and core can also change how a string feels.
Where the unit weights come from
Plain steel uses a solid-cylinder model and nominal steel density. Wound entries use selected D’Addario unit weights with log interpolation between listed gauges. Manufacturer construction, winding length and availability vary.
References
Questions at the bench
Which of the 12–53 acoustic strings uses plain-steel data?
The .012 high E and .016 B. This set uses phosphor bronze for the four wound strings.
Can I compare phosphor bronze and nickel with the same low E gauge?
Yes where both tables cover that gauge. Different wrap and core construction can change mass even when outside diameter matches.