Worked example · String Tension & Gauge

A 34–37-inch five-string bass in standard B

A multiscale bass carries a 130 mil low B at 37 in and a 45 mil G at 34 in. Compare pull across all five strings before selecting a low B.

Try this Try a 125 mil B and compare the suggested gauge and its residual difference from the 43 lbf target.

Inputs

View results ↓
in12–45 in
in12–45 in
Hz400–480 Hz
lbfEnter zero to match the current average. 0–112.404 lbf

Strings · bass to treble

String 1
mil4–150 mil
String 2
mil4–150 mil
String 3
mil4–150 mil
String 4
mil4–150 mil
String 5
mil4–150 mil
Total neck pull
235.96 lbf
Average per string
47.19 lbf
Balance target
43 lbf

String tension and neck pull

String tension and neck pullBars show tension by string. The dashed line marks the balance target and the neck view follows the selected scale endpoints. STRING FORCENECK PULLB040.8E145.9A152.8D253.7G242.8Target 43 lbf236 lbfFanned scale
Bars show tension by string. The dashed line marks the balance target and the neck view follows the selected scale endpoints.

String forces and suggested gauges
PitchHzConstructionScale (in)Gauge (mil)Tension (lbf)Suggested (mil)At suggestion (lbf)From target (lbf)
B030.87Nickel-wound3713040.813542.7-0.3
E141.2Nickel-wound36.2510545.8610041.53-1.47
A155Nickel-wound35.58552.817541.46-1.54
D273.42Nickel-wound34.756553.666044.871.87
G298Nickel-wound344542.834542.83-0.17
Total neck pull 235.96 lbf

How the calculation works

From pitch to pull

Mersenne’s law gives T = μ(2Lf)². The math uses kilograms per meter for linear mass, meters for vibrating length and hertz for pitch. Each successive string takes one evenly spaced step between the two scale endpoints.

What “balanced” means here

The calculator searches the selected construction table for the stocked diameter whose force is closest to the target. Compare suggested force with target force before treating a set as balanced. Gauge, wrap and core can also change how a string feels.

Where the unit weights come from

Plain steel uses a solid-cylinder model and nominal steel density. Wound entries use selected D’Addario unit weights with log interpolation between listed gauges. Manufacturer construction, winding length and availability vary.

References

Questions at the bench

Why can a 37-inch B feel firm without using a 145 mil string?

The longer scale raises force in proportion to length squared at the same pitch and gauge.

How much longer is the second string in the 34–37-inch five-string fan?

Its modeled scale is 36.25 in. Each string steps down by 0.75 in toward the treble side.