Worked example · String Tension & Gauge
Seven-string drop A on a 25.5–27-inch fan
A seven-string uses a .064 A1 and a 27 in bass scale while keeping the high strings on a familiar 25.5 in scale.
Try this Set both endpoint scales to 25.5 in and watch the low A bar shorten while the high E stays put.
Inputs
Results
Back to inputs ↑- Total neck pull
- 126.36 lbf
- Average per string
- 18.05 lbf
- Balance target
- 17 lbf
String tension and neck pull
| Pitch | Hz | Construction | Scale (in) | Gauge (mil) | Tension (lbf) | Suggested (mil) | At suggestion (lbf) | From target (lbf) |
|---|---|---|---|---|---|---|---|---|
| A1 | 55 | Nickel-wound | 27 | 64 | 17.13 | 64 | 17.13 | 0.13 |
| E2 | 82.41 | Nickel-wound | 26.75 | 46 | 19.24 | 44 | 17.71 | 0.71 |
| A2 | 110 | Nickel-wound | 26.5 | 36 | 21.1 | 32 | 17.03 | 0.03 |
| D3 | 146.83 | Nickel-wound | 26.25 | 26 | 19.5 | 24 | 16.71 | -0.29 |
| G3 | 196 | Plain steel | 26 | 17 | 17.32 | 17 | 17.32 | 0.32 |
| B3 | 246.94 | Plain steel | 25.75 | 13 | 15.77 | 13 | 15.77 | -1.23 |
| E4 | 329.63 | Plain steel | 25.5 | 10 | 16.3 | 10 | 16.3 | -0.7 |
Input settings
- String family Guitar
- Treble scale 25.5 in
- Bass scale 27 in
- A4 reference 440 Hz
- Balance target per string 17 lbf
- string 1 · Pitch A1
- string 1 · Gauge 64 mil
- string 1 · Construction Nickel-wound
- string 2 · Pitch E2
- string 2 · Gauge 46 mil
- string 2 · Construction Nickel-wound
- string 3 · Pitch A2
- string 3 · Gauge 36 mil
- string 3 · Construction Nickel-wound
- string 4 · Pitch D3
- string 4 · Gauge 26 mil
- string 4 · Construction Nickel-wound
- string 5 · Pitch G3
- string 5 · Gauge 17 mil
- string 5 · Construction Plain steel
- string 6 · Pitch B3
- string 6 · Gauge 13 mil
- string 6 · Construction Plain steel
- string 7 · Pitch E4
- string 7 · Gauge 10 mil
- string 7 · Construction Plain steel
How the calculation works
From pitch to pull
Mersenne’s law gives T = μ(2Lf)². The math uses kilograms per meter for linear mass, meters for vibrating length and hertz for pitch. Each successive string takes one evenly spaced step between the two scale endpoints.
What “balanced” means here
The calculator searches the selected construction table for the stocked diameter whose force is closest to the target. Compare suggested force with target force before treating a set as balanced. Gauge, wrap and core can also change how a string feels.
Where the unit weights come from
Plain steel uses a solid-cylinder model and nominal steel density. Wound entries use selected D’Addario unit weights with log interpolation between listed gauges. Manufacturer construction, winding length and availability vary.
References
Questions at the bench
Does the 27-inch low A change the middle strings on a seven-string fan?
Yes. The calculator interpolates scale lengths from bass to treble. The central string is halfway between the endpoint lengths.
Why compare gauge at the A1 string before changing the whole seven-string set?
The remaining six pitches in this preset are unchanged from standard 7-string tuning. You can isolate the effect of the low A first.