Worked example · String Tension & Gauge

Seven-string drop A on a 25.5–27-inch fan

A seven-string uses a .064 A1 and a 27 in bass scale while keeping the high strings on a familiar 25.5 in scale.

Try this Set both endpoint scales to 25.5 in and watch the low A bar shorten while the high E stays put.

Inputs

View results ↓
in12–45 in
in12–45 in
Hz400–480 Hz
lbfEnter zero to match the current average. 0–112.404 lbf

Strings · bass to treble

String 1
mil4–150 mil
String 2
mil4–150 mil
String 3
mil4–150 mil
String 4
mil4–150 mil
String 5
mil4–150 mil
String 6
mil4–150 mil
String 7
mil4–150 mil
Total neck pull
126.36 lbf
Average per string
18.05 lbf
Balance target
17 lbf

String tension and neck pull

String tension and neck pullBars show tension by string. The dashed line marks the balance target and the neck view follows the selected scale endpoints. STRING FORCENECK PULLA117.1E219.2A221.1D319.5G317.3B315.8E416.3Target 17 lbf126.4 lbfFanned scale
Bars show tension by string. The dashed line marks the balance target and the neck view follows the selected scale endpoints.

String forces and suggested gauges
PitchHzConstructionScale (in)Gauge (mil)Tension (lbf)Suggested (mil)At suggestion (lbf)From target (lbf)
A155Nickel-wound276417.136417.130.13
E282.41Nickel-wound26.754619.244417.710.71
A2110Nickel-wound26.53621.13217.030.03
D3146.83Nickel-wound26.252619.52416.71-0.29
G3196Plain steel261717.321717.320.32
B3246.94Plain steel25.751315.771315.77-1.23
E4329.63Plain steel25.51016.31016.3-0.7
Total neck pull 126.36 lbf

How the calculation works

From pitch to pull

Mersenne’s law gives T = μ(2Lf)². The math uses kilograms per meter for linear mass, meters for vibrating length and hertz for pitch. Each successive string takes one evenly spaced step between the two scale endpoints.

What “balanced” means here

The calculator searches the selected construction table for the stocked diameter whose force is closest to the target. Compare suggested force with target force before treating a set as balanced. Gauge, wrap and core can also change how a string feels.

Where the unit weights come from

Plain steel uses a solid-cylinder model and nominal steel density. Wound entries use selected D’Addario unit weights with log interpolation between listed gauges. Manufacturer construction, winding length and availability vary.

References

Questions at the bench

Does the 27-inch low A change the middle strings on a seven-string fan?

Yes. The calculator interpolates scale lengths from bass to treble. The central string is halfway between the endpoint lengths.

Why compare gauge at the A1 string before changing the whole seven-string set?

The remaining six pitches in this preset are unchanged from standard 7-string tuning. You can isolate the effect of the low A first.