Worked example · Tube Amp Bias
A 6550 Class AB stage below the reference band
A power amp uses a 35 W 6550 variant and its service record shows a conservative 38 mA plate current at idle.
Use readings already documented by a qualified technician. An amplifier can retain lethal voltage after being unplugged.
Try this Compare the measured plate current with the 55% reference current. Read the amp’s service specification for the intended setting.
Inputs
Results
Back to inputs ↑- Idle plate dissipation
- 18.81 W
- Of maximum
- 53.74 %
- Plate current per tube
- 38 mA
Plate dissipation zones
| Plate to cathode (V) | Cathode (mA) | Plate (mA) | Maximum plate rating (W) |
|---|---|---|---|
| 495 | 43 | 38 | 35 |
| 55% plate (mA) | 70% plate (mA) | 100% plate (mA) |
|---|---|---|
| 38.89 | 49.49 | 70.71 |
Input settings
- Power tube preset 6550
- Output stage class Class AB
- Bias method Fixed bias
- Maximum plate dissipation 35 W
- Plate to ground 495 V
- Cathode to ground 0 V
- Cathode reading type Across a 1 Ω shunt (mV)
- Total cathode reading 43 mV
- Tubes in this reading 1
- Screen current per tube 5 mA
How the calculation works
Use the actual plate-to-cathode voltage
Subtract the cathode-to-ground reading from the plate-to-ground reading. A 1 Ω shunt gives the same numerical reading in millivolts as current in milliamps.
Separate plate and screen
Divide a shared cathode reading by the number of tubes, then subtract per-tube screen current. Idle plate watts equal plate-to-cathode volts × plate amps.
Read the band in context
The 55–70% band is a Class AB comparison range. Use the manufacturer’s idle specification and load line for the actual stage, especially for Class A. Presets reflect example data-sheet ratings and can be edited.
References
Questions at the bench
Is this 6550’s below-band reading automatically a fault?
The band is a point of comparison. The amp maker can specify a lower idle point for a particular circuit or service condition.
How does a 42 W 6550 variant change this example?
Keep the documented readings and enter 42 W if that is the correct data-sheet maximum. The displayed percentage will be lower.