Worked example · Tube Amp Bias
A 6L6GC pair with a shared 96 mA reading
A matched-pair service record reports 96 mA for both 6L6GCs together, with 5 mA screen current estimated per tube.
Use readings already documented by a qualified technician. An amplifier can retain lethal voltage after being unplugged.
Try this Select one tube in the reading and notice how the calculation changes. Restore two for the shared measurement.
Inputs
Results
Back to inputs ↑- Idle plate dissipation
- 19.995 W
- Of maximum
- 66.65 %
- Plate current per tube
- 43 mA
Plate dissipation zones
- A shared reading gives a per-tube average. It can hide a hotter or colder individual tube.
| Plate to cathode (V) | Cathode (mA) | Plate (mA) | Maximum plate rating (W) |
|---|---|---|---|
| 465 | 48 | 43 | 30 |
| 55% plate (mA) | 70% plate (mA) | 100% plate (mA) |
|---|---|---|
| 35.48 | 45.16 | 64.52 |
Input settings
- Power tube preset 6L6GC
- Output stage class Class AB
- Bias method Fixed bias
- Maximum plate dissipation 30 W
- Plate to ground 465 V
- Cathode to ground 0 V
- Cathode reading type Cathode current (mA)
- Total cathode reading 96 mA
- Tubes in this reading 2
- Screen current per tube 5 mA
How the calculation works
Use the actual plate-to-cathode voltage
Subtract the cathode-to-ground reading from the plate-to-ground reading. A 1 Ω shunt gives the same numerical reading in millivolts as current in milliamps.
Separate plate and screen
Divide a shared cathode reading by the number of tubes, then subtract per-tube screen current. Idle plate watts equal plate-to-cathode volts × plate amps.
Read the band in context
The 55–70% band is a Class AB comparison range. Use the manufacturer’s idle specification and load line for the actual stage, especially for Class A. Presets reflect example data-sheet ratings and can be edited.
References
Questions at the bench
Should I subtract one 5 mA screen term from the entire 96 mA pair?
Divide the pair reading by two first, then subtract 5 mA from each tube’s 48 mA average.
Can the shared 6L6GC reading reveal that one tube runs hotter?
The tool gives an average from the shared value. Separate recorded currents are needed to compare individual tubes.