Worked example · Tube Amp Bias

A 6L6GC pair with a shared 96 mA reading

A matched-pair service record reports 96 mA for both 6L6GCs together, with 5 mA screen current estimated per tube.

Use readings already documented by a qualified technician. An amplifier can retain lethal voltage after being unplugged.

Try this Select one tube in the reading and notice how the calculation changes. Restore two for the shared measurement.

Inputs

View results ↓
WUse the data sheet for the exact tube in your amp. 1–150 W
V0.1–1,000 V
V0–200 V
mA0–2,000 mA
Use one for an individual reading. 1–8
mA0–100 mA
Idle plate dissipation
19.995 W
Of maximum
66.65 %
Plate current per tube
43 mA

Plate dissipation zones

Plate dissipation zonesThe dot shows your idle point. Curves show constant dissipation as a percentage of the entered maximum plate rating. Plate current (mA)Plate-to-cathode (V)014521291424366358184Class AB · 66.7%55–70% AB reference100% plate rating
The dot shows your idle point. Curves show constant dissipation as a percentage of the entered maximum plate rating.
  • A shared reading gives a per-tube average. It can hide a hotter or colder individual tube.

Per-tube electrical values
Plate to cathode (V)Cathode (mA)Plate (mA)Maximum plate rating (W)
465484330
Class AB reference at the entered voltage
55% plate (mA)70% plate (mA)100% plate (mA)
35.4845.1664.52
Idle plate dissipation 19.995 W

How the calculation works

Use the actual plate-to-cathode voltage

Subtract the cathode-to-ground reading from the plate-to-ground reading. A 1 Ω shunt gives the same numerical reading in millivolts as current in milliamps.

Separate plate and screen

Divide a shared cathode reading by the number of tubes, then subtract per-tube screen current. Idle plate watts equal plate-to-cathode volts × plate amps.

Read the band in context

The 55–70% band is a Class AB comparison range. Use the manufacturer’s idle specification and load line for the actual stage, especially for Class A. Presets reflect example data-sheet ratings and can be edited.

References

Questions at the bench

Should I subtract one 5 mA screen term from the entire 96 mA pair?

Divide the pair reading by two first, then subtract 5 mA from each tube’s 48 mA average.

Can the shared 6L6GC reading reveal that one tube runs hotter?

The tool gives an average from the shared value. Separate recorded currents are needed to compare individual tubes.