Worked example · Tube Amp Bias
A KT88 at 535 V with a 42 W data-sheet rating
A KT88 service sheet specifies a 42 W plate rating and documents 54 mA at 535 V while idle. The screen component is 5 mA.
Use readings already documented by a qualified technician. An amplifier can retain lethal voltage after being unplugged.
Try this Compare the output if the exact tube’s sheet instead specifies 35 W, keeping the measured data unchanged.
Inputs
Results
Back to inputs ↑- Idle plate dissipation
- 26.215 W
- Of maximum
- 62.42 %
- Plate current per tube
- 49 mA
Plate dissipation zones
| Plate to cathode (V) | Cathode (mA) | Plate (mA) | Maximum plate rating (W) |
|---|---|---|---|
| 535 | 54 | 49 | 42 |
| 55% plate (mA) | 70% plate (mA) | 100% plate (mA) |
|---|---|---|
| 43.18 | 54.95 | 78.5 |
Input settings
- Power tube preset KT88
- Output stage class Class AB
- Bias method Fixed bias
- Maximum plate dissipation 42 W
- Plate to ground 535 V
- Cathode to ground 0 V
- Cathode reading type Across a 1 Ω shunt (mV)
- Total cathode reading 54 mV
- Tubes in this reading 1
- Screen current per tube 5 mA
How the calculation works
Use the actual plate-to-cathode voltage
Subtract the cathode-to-ground reading from the plate-to-ground reading. A 1 Ω shunt gives the same numerical reading in millivolts as current in milliamps.
Separate plate and screen
Divide a shared cathode reading by the number of tubes, then subtract per-tube screen current. Idle plate watts equal plate-to-cathode volts × plate amps.
Read the band in context
The 55–70% band is a Class AB comparison range. Use the manufacturer’s idle specification and load line for the actual stage, especially for Class A. Presets reflect example data-sheet ratings and can be edited.
References
Questions at the bench
Why does changing the KT88 rating move the zone curves but leave plate watts alone?
The watts come from the measured voltage and corrected current. The percentage normalizes that result by the data-sheet rating.
How can the KT88 stage sit inside the comparison band with relatively high voltage?
The plate current is also part of the product, and this fixture uses a 42 W maximum for its exact variant.