Worked example · Tube Amp Bias
A cathode-biased EL84 pair above its plate rating
An older service record lists 94 mA across two EL84s. At 327 V plate-to-cathode, the calculated idle power exceeds the entered 12 W rating.
Use readings already documented by a qualified technician. An amplifier can retain lethal voltage after being unplugged.
Try this Change the reading to 80 mA and see where the idle point moves relative to the 100% curve.
Inputs
Results
Back to inputs ↑- Idle plate dissipation
- 14.061 W
- Of maximum
- 117.17 %
- Plate current per tube
- 43 mA
Plate dissipation zones
- Calculated idle plate dissipation exceeds the entered plate rating.
- A shared reading gives a per-tube average. It can hide a hotter or colder individual tube.
| Plate to cathode (V) | Cathode (mA) | Plate (mA) | Maximum plate rating (W) |
|---|---|---|---|
| 327 | 47 | 43 | 12 |
| 55% plate (mA) | 70% plate (mA) | 100% plate (mA) |
|---|---|---|
| 20.18 | 25.69 | 36.7 |
Input settings
- Power tube preset EL84
- Output stage class Class AB
- Bias method Cathode bias
- Maximum plate dissipation 12 W
- Plate to ground 338 V
- Cathode to ground 11 V
- Cathode reading type Cathode current (mA)
- Total cathode reading 94 mA
- Tubes in this reading 2
- Screen current per tube 4 mA
How the calculation works
Use the actual plate-to-cathode voltage
Subtract the cathode-to-ground reading from the plate-to-ground reading. A 1 Ω shunt gives the same numerical reading in millivolts as current in milliamps.
Separate plate and screen
Divide a shared cathode reading by the number of tubes, then subtract per-tube screen current. Idle plate watts equal plate-to-cathode volts × plate amps.
Read the band in context
The 55–70% band is a Class AB comparison range. Use the manufacturer’s idle specification and load line for the actual stage, especially for Class A. Presets reflect example data-sheet ratings and can be edited.
References
Questions at the bench
How can an EL84 pair share a cathode resistor and still use a per-tube rating?
The formula averages the shared current across two tubes, then computes watts against one tube’s rating.
What does the EL84 chart show when the idle dot is above 100%?
It shows that the entered measurements and rating put the calculated idle point over the plate limit. Review the readings and rating with a technician.