Single-pass laminar oil circuit
High viscosity keeps the oil flow laminar in an exchanger with one tube pass.
Tube bundle and pass routing
ΔP = [f × (L/Dᵢ) × nₚ + 4(nₚ − 1)] × ρv²/2
- Required tubes
- 162
- Tube velocity
- 0.206m/s
- Tube ΔP
- 4.4655kPa
- Reynolds
- 49.819
- Tube velocity is below the 0.9 m/s fouling screen.
Inputs
Calculated results
- Required tubes
- 162
- Tube velocity
- 0.206 m/s
- Tube-side pressure drop
- 4.4655 kPa
- Tube Reynolds number
- 49.819
- Estimated tubes that fit
- 277
- Tubes per pass
- 162
- Installed outside area
- 29.086 m²
- Tube inside diameter
- 15.748 mm
- Tube center pitch
- 23.812 mm
- Straight tube loss
- 4.4655 kPa
- Return pass loss
- 0 kPa
- Darcy friction factor
- 1.2847
Worked solution
Preset calculation · Metric SI
- Divide the required area by the area per tube and round up to a complete pass grouping. The result is 162 tubes.
- Put the flow through 162 tubes per pass. The resulting tube speed and Reynolds number are 0.206 m/s and 49.819.
- Add 4.4655 kPa of straight loss and 0 kPa of return loss.
Verify that the friction factor follows 64/Re and that there is no return-pass loss.
Calculation basis
Required outside area divided by πDₒL gives the raw tube count. Round up to fill complete passes. Bundle capacity counts centers on the selected pitch lattice inside a circular limit after bundle clearance.
The bundle screen uses a centered lattice and omits pass-partition lanes, tie rods, and detailed tubesheet constraints. Confirm actual tube count with a layout drawing.
Straight loss uses Darcy–Weisbach with 64/Re for laminar flow and Haaland for turbulent flow. Add K = 4 per return pass. The default 0.9–2.4 m/s screening band is for initial liquid-service review.
Methodology and references