Solar Blanket Pool Evaporation and Heat Savings
Compare covered and uncovered pool evaporation using a 16-hour blanket schedule and an 82°F maintenance target.
Inputs
Results ↓Results
Example estimate- Collector area in metric
- 40.7 m²
- Collector-to-pool surface ratio
- 93.1 %
- Collector area to maintain target
- 437.8 ft²
- Whole-pool warm-up energy
- 0 BTU
- Daily load during warm-up
- 419,820 BTU/day
- Daily loss at target
- 419,820 BTU/day
- Required heat pump output
- 34,985 BTU/h
- Entered heat pump warm-up time
- 0 days
- Heat pump running time
- 0 hours
- Water temperature target
- 82 °F
- The model assumes steady average weather and omits direct sunshine into the pool and ground losses. Compare against local collector output.
Calculation inputs
- Pool water surface area
- 470 ft²
- Pool volume
- 17000 US gal
- Starting water temperature
- 82 °F
- Desired temperature increase
- 0 °F
- Desired heat-up time
- 3 days
- Average outdoor air temperature
- 72 °F
- Outdoor relative humidity
- 50 %
- Wind at water surface
- 3 mph
- Solar blanket use
- 16 h/day
- Covered evaporation reduction
- 90 %
- Peak sun hours at the collectors
- 5.5 h/day
- Net useful collector efficiency
- 55 %
- Heat pump output at site conditions
- 110000 BTU/h
- Available heat pump run time
- 12 h/day
Worked example
At the target water temperature, covering the pool for 16 hours at 90% effectiveness reduces the modeled evaporation component by 60%. Compare zero cover hours to see the change in daily heat needed.
Suggested solar collector area 437.8 ft²
What to check next
Use realistic hours that the cover stays on, including windy nights and swim schedules. The actual cover fit, solar exposure and weather can change the result.
Formulas and assumptions
- Warm-up energy
- BTU = 8.34 × US gallons × temperature rise in °F. Divide by the desired heat-up days and add average daily losses.
- Surface loss
- The air-speed evaporation correlation uses water area, vapor-pressure difference and water-level wind. Blanket use reduces evaporation during covered hours. Surface-only losses use a simple temperature-difference allowance.
- Collector and heat pump
- Size from the larger of the average warm-up load and the target-temperature daily loss. Collector ft² = design daily BTU ÷ useful BTU per ft² per day. Heat pump BTU/h = design daily BTU ÷ run hours.
Frequently asked questions
Does a blanket that blocks 90% of evaporation save 90% of daily heat?
The reduction applies only to evaporation during covered hours. The daily heat total also includes other surface losses and any warm-up load.
Can a solar blanket reduce the collector area needed just to maintain temperature?
Lower evaporation reduces modeled maintenance BTU. Compare covered and uncovered daily losses using the same water and air conditions.