Tankless Water Heater GPM & BTU Calculator

Add simultaneous hot-water fixtures, estimate winter temperature rise, and compare tankless gas input with electric kW, current and circuit load.

Simultaneous hot-water draw
Water temperature and heater

Results

Example estimate
Peak hot-side demand4.6 GPM
Showers 4 GPM Dishwasher 0 GPM Clothes washer 0 GPM Faucets 0.6 GPM
The bars include fixtures drawing hot water at the same time.
Winter inlet temperature
48 °F
Required temperature rise
72 °F
Useful heat into water
165,600 BTU/h
Gas input at steady efficiency
176,170 BTU/h
Electric input
49.02 kW
Total operating current
204.3 A
Operating current per circuit
68.1 A
Breaker comparison per circuit
70 A
  • Use the manufacturer’s flow-at-rise chart and listed circuit schedule. Breaker figures here are only comparisons.

Worked example

Two showers and a faucet use 4.6 GPM of hot water in this example. A 48°F inlet and a 120°F outlet require a 72°F rise during that simultaneous draw.

Peak hot-side demand 4.6 GPM

Formulas and assumptions

Fixture flow
Peak hot-side GPM = Σ(simultaneous fixture count × hot-side GPM each). Temperature rise = heater outlet minus winter inlet.
Heater input
Heat delivered to water ≈ 500 × GPM × rise in °F. Divide by steady gas efficiency for burner input, or by 3,412.14 and electric efficiency for electric kW.
Circuit comparison
Amps = kW × 1,000 ÷ volts for the single-phase example. Split equally among the assumed circuits and compare with the next standard breaker size. Use the manufacturer’s circuit schedule for installation.

Frequently asked questions

Should I use total shower flow or hot-side flow to size a tankless heater?

Use only the portion delivered by the heater. If a shower mixes hot and cold water, its hot fraction is (mixed temperature − inlet temperature) ÷ (heater outlet − inlet temperature).

Why can the same tankless heater deliver fewer GPM in winter?

Cold inlet water requires a larger temperature rise. The same power transfers less hot water per minute at a greater rise.

Can UEF stand in for a tankless heater’s peak thermal efficiency?

UEF describes a test-cycle result. A UEF-based input here is an optional screening comparison. Confirm peak flow and burner input from the model’s performance chart.