Heat Pump vs. Gas Furnace Cost Calculator
Compare heat pump, gas, propane, oil and resistance heating per MMBtu. Estimate annual bills, simple payback and an economic balance temperature.
Inputs
Results ↓Results
Example estimate- Seasonal heat pump COP
- 3 COP
- Selected comparison
- Natural gas
- Annual savings vs. comparison
- −$49.15 / year
- Simple payback
- No annual energy payback
- Break-even COP
- 3.18 COP
- Economic balance point
- 37.2 °F
| Energy source | Per MMBtu | Annual |
|---|---|---|
| Heat pump | $15.63 | $859.68 |
| Natural gas | $14.74 | $810.53 |
| Propane | $32.09 | $1,765 |
| Heating oil | $31 | $1,705.25 |
| Electric resistance | $46.89 | $2,579.03 |
Calculation inputs
- Annual heat delivered indoors
- 55 MMBtu
- Seasonal efficiency source
- Seasonal COP
- Seasonal COP
- 3
- Operating COP at 47°F
- 3.6
- Operating COP at 5°F
- 1.8
- Backup fuel for comparison
- Natural gas
- Added heat pump installation cost
- 3000 $
- Electricity price
- 0.16 $/kWh
- Natural gas price
- 1.4 $/therm
- Gas furnace AFUE
- 95 %
- Propane price
- 2.7 $/gal
- Propane furnace AFUE
- 92 %
- Heating oil price
- 3.65 $/gal
- Oil furnace AFUE
- 85 %
Worked example
Compare five ways to deliver 55 MMBtu of space heat. Use the seasonal COP for the annual bill and the COP values at 5°F and 47°F for the separate outdoor-temperature comparison.
Annual heat pump energy cost $859.68 / year
Formulas and assumptions
- Delivered heat cost
- Cost per MMBtu = price per unit × 1,000,000 ÷ (BTU per unit × efficiency). Seasonal COP can be estimated with HSPF2 ÷ 3.412.
- Economic balance point
- Break-even COP = electric resistance cost per MMBtu ÷ backup heat cost per MMBtu. Interpolate between the entered 5°F and 47°F COP values.
- Simple payback
- Annual energy cost = delivered heat cost × annual load. Payback = positive added installation cost ÷ positive annual savings.
Frequently asked questions
How is economic balance temperature different from a heat pump capacity balance point?
The economic point compares the price of delivered heat. The capacity point is the outdoor temperature where equipment output equals building heat loss. A dual-fuel setup may need to honor both.
Can I use HSPF2 to predict heat pump COP at 5°F?
Use HSPF2 as a seasonal test-efficiency proxy. For the 5°F point, take the operating COP from the manufacturer’s performance table.
Which utility charges belong in heating payback?
Use marginal energy rates that change as you use more fuel. Add or subtract any fixed account charges only if the installation changes which accounts you keep.