Solar Pool Collector Area for a Windy Yard

See how water-level wind and cover hours can change solar collector area for an exposed outdoor pool.

Pool, weather and cover

Applies to evaporation during the covered hours.

Collector and heat pump

Results

Example estimate
Suggested solar collector area1,153.2 ft²
Water warm-up per day 210,168 BTU Evaporation loss 672,831 BTU Other surface loss 72,000 BTU
Average-day load during the selected warm-up period.
Collector area in metric
107.1 m²
Collector-to-pool surface ratio
230.6 %
Collector area to maintain target
1,102.3 ft²
Whole-pool warm-up energy
1,050,840 BTU
Daily load during warm-up
954,999 BTU/day
Daily loss at target
912,894 BTU/day
Required heat pump output
79,583 BTU/h
Entered heat pump warm-up time
1.83 days
Heat pump running time
21.9 hours
Water temperature target
80 °F
  • The model assumes steady average weather and omits direct sunshine into the pool and ground losses. Compare against local collector output.
  • Evaporation is highly sensitive to water-level wind. The outdoor wind adjustment is a rough screening estimate.

Worked example

An exposed pool has higher modeled evaporation than a sheltered pool at the same temperature and RH. Compare 6 mph with 2 mph at water level and look at collector area as well as the heat-loss breakdown.

Suggested solar collector area 1,153.2 ft²

What to check next

Check actual wind across the water rather than relying on an airport reading. Treat higher-wind results as screening estimates and compare several typical nights.

Formulas and assumptions

Warm-up energy
BTU = 8.34 × US gallons × temperature rise in °F. Divide by the desired heat-up days and add average daily losses.
Surface loss
The air-speed evaporation correlation uses water area, vapor-pressure difference and water-level wind. Blanket use reduces evaporation during covered hours. Surface-only losses use a simple temperature-difference allowance.
Collector and heat pump
Size from the larger of the average warm-up load and the target-temperature daily loss. Collector ft² = design daily BTU ÷ useful BTU per ft² per day. Heat pump BTU/h = design daily BTU ÷ run hours.

Frequently asked questions

Where should I measure wind for an outdoor solar pool estimate?

Use representative airspeed close to the water surface. Fences, buildings and landscaping affect the air that reaches the pool.

Can a windbreak change solar pool collector sizing?

It can reduce evaporation by lowering surface wind. Account for any new shading on the pool or collectors before judging the net effect.

More sizing examples

Open the general solar pool heating calculator